LONDONDERRY, NH —
OSHA Inspection: NEW HAMPSHIRE PRECISION METAL FABRICATORS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEW HAMPSHIRE PRECISION METAL FABRICATORS, INC. in 15 INDUSTRIAL DRIVE, LONDONDERRY, NH 03053 (NAICS 332322). OSHA activity number 332788439.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEW HAMPSHIRE PRECISION METAL FABRICATORS, INC.
- Site address
- 15 INDUSTRIAL DRIVE
- City
- LONDONDERRY
- State
- NH
- ZIP
- 03053
- Mailing
- 15 INDUSTRIAL DRIVE, LONDONDERRY, NH 03053
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 75
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 A04
- Issued
- Aug 27, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a. Prior written approval was not obtained for the fork attachment which was used on the caterpillar (model GC40K S/N# AT8702361) Forklift.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.215 A04
- Issued
- Aug 27, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a. The Bradley and Walker grinder was not equipped with an adequate work rest.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.145 F03
- Issued
- Aug 27, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(f)(3): Tags were not used as a means to prevent accidental injury or illness to employees who were exposed to hazardous or potentially hazardous conditions, equipment or operations which were out of the ordinary, unexpected or not readily: a. Warring tags were not provided for the Porter Cable bench grinder informing employees that the grinder was out service and could not to use until adequate machine guarding was reinstalled. b. Warring tags were not provided for the Clarke Metalworker 6 modal# BT10058 bench grinder informing employees that the grinder was out service and could not to use until adequate machine guarding was reinstalled.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.215 B09
- Issued
- Aug 27, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a. The tongue guard was missing on the Bradley and Walker grinder.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.242 B
- Issued
- Aug 27, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. Compressed air used at Amada (model Viper 358 King. S/N C410S005) workstations for cleaning purposes was 90 p.s.i. b. Compressed air used at Timesaver (model 137-1HDMW S/N 219781) workstations for cleaning purposes was 87 p.s.i. c. Compressed air used at (Bridgebort grill press) workstations for cleaning purposes was 90 p.s.i.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.303 G01 I
- Issued
- Aug 27, 2012
- Abate by
- Aug 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: a. The area in front of the circuit breaker panel was used for storage of trash and other materials.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at NEW Hampshire Precision Metal Fabricators, INC.
View NEW Hampshire Precision Metal Fabricators, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332788439.