Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEW HAMPSHIRE PRECISION METAL FABRICATORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEW HAMPSHIRE PRECISION METAL FABRICATORS, INC. in 15 INDUSTRIAL DRIVE, LONDONDERRY, NH 03053 (NAICS 332322). OSHA activity number 332788439.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NEW Hampshire Precision Metal Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for NEW Hampshire Precision Metal Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15 INDUSTRIAL DRIVE
City
LONDONDERRY
State
NH
ZIP
03053
Mailing
15 INDUSTRIAL DRIVE, LONDONDERRY, NH 03053
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
75
Ownership type
A

6 citations on file for this inspection.

1910.178 A04

Serious Gravity 5 1 exposed
Issued
Aug 27, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.178(a)(4):  Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:      a.  Prior written approval was not obtained for the fork attachment which was used on the caterpillar (model GC40K S/N# AT8702361) Forklift.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.215 A04

Deleted Serious Gravity 5 2 exposed
Issued
Aug 27, 2012
Abate by
Aug 28, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:      a.  The Bradley and Walker grinder was not equipped with an adequate work rest.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.145 F03

Other-than-serious 2 exposed
Issued
Aug 27, 2012
Abate by
Aug 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.145(f)(3):  Tags were not used as a means to prevent accidental injury or illness to employees who were exposed to hazardous or potentially hazardous conditions, equipment or operations which were out of the ordinary, unexpected or not readily:    a.  Warring tags were not provided for the Porter Cable bench grinder informing employees that the grinder was out service and could not to use until adequate machine guarding was reinstalled.     b.  Warring tags were not provided for the Clarke Metalworker 6 modal# BT10058 bench grinder informing employees that the grinder was out service and could not to use until adequate machine guarding was reinstalled.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 2 exposed
Issued
Aug 27, 2012
Abate by
Aug 28, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.215(b)(9):  Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    a.  The tongue guard was missing on the Bradley and Walker grinder.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.242 B

Serious Gravity 5 5 exposed
Issued
Aug 27, 2012
Abate by
Aug 28, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a.  Compressed air used at Amada (model Viper 358 King. S/N C410S005) workstations for cleaning purposes was 90 p.s.i.    b.  Compressed air used at Timesaver (model 137-1HDMW S/N 219781) workstations for cleaning purposes was 87 p.s.i.    c.  Compressed air used at (Bridgebort grill press) workstations for cleaning purposes was 90 p.s.i.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.303 G01 I

Other-than-serious 1 instance 6 exposed
Issued
Aug 27, 2012
Abate by
Aug 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i):  Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:    a.  The area in front of the circuit breaker panel was used for storage of trash and other materials.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NEW Hampshire Precision Metal Fabricators, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332788439.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.