LITTLE NECK, NY ·
OSHA Inspection: FENGHA CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FENGHA CONSTRUCTION INC. in 248-52 RUSHMORE AVENUE, LITTLE NECK, NY 11362 (NAICS 236116). OSHA activity number 332789510.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FENGHA CONSTRUCTION INC.
- Site address
- 248-52 RUSHMORE AVENUE
- City
- LITTLE NECK
- State
- NY
- ZIP
- 11362
- Mailing
- 137-60 LABURNUM AVENUE, FLUSHING, NY 11355
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 7
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.102 A01
- Issued
- May 21, 2012
- Penalty
- Initial $2,550 · Current $1,125 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about February 29, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Employee drilling holes in a piece of steel without eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- · I (S) $1125
- · Z (S) $2550
1926.451 B01
- Issued
- May 21, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about February 9, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Tubular welded frame scaffold was missing a was planked with two planks leaving 23 inches unplanked. b) On or about February 29, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Tubular welded frame scaffold was missing 5.5 inches of planking. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- · I (S) $1500
- · Z (S) $3000
1926.451 G01 VII
- Issued
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about February 29, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Employee was on tubular welded frame scaffold to a height of 25 feet above the next lower level without fall protection . WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.454 A
- Issued
- May 21, 2012
- Abate by
- Jul 3, 2012
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about February 9, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Employee could not identify scaffold hazards scaffolds not fully planked due to lack of training. b) On or about February 9, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Employees were on scaffold again and exposed to hazards falls up to 25 and un-planked scaffold without training. WRITTEN ABATEMENT DOCUMENTATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $4200
1926.501 B01
- Issued
- May 21, 2012
- Penalty
- Initial $2,550 · Current $610 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about February 9, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Two employees standing at the edge of the basement wall 8 above the next lower level trying to lift the end of a 22 foot long I-beam. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- · I (S) $610
- · Z (S) $2550
1926.1053 B01
- Issued
- May 21, 2012
- Penalty
- Initial $1,530 · Current $765 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about February 29, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Employee working on tubular welded frame scaffold was using the top of a step ladder that was 10 inches below the working surface to access the working surface. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- · I (S) $765
- · Z (S) $1530
1926.1053 B13
- Issued
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about February 29, 2012Job site at 248-52 Rushmore Avenue Little Neck, NY 11362 Employee working on tubular welded frame scaffold was using the top of a step ladder that was 10 inches below the working surface to access the working surface. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 236116)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332789510.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.