Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRIME CARE MEDICAL SUPPLIES INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRIME CARE MEDICAL SUPPLIES INC in 25 CORPORATE DRIVE, HOLTSVILLE, NY 11742 (NAICS 423450). OSHA activity number 332790682.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prime Care Medical Supplies INC — free Get an email when a new federal OSHA severe-injury report for Prime Care Medical Supplies INC is published. One employer, no account, unsubscribe in one click.
Site address
25 CORPORATE DRIVE
City
HOLTSVILLE
State
NY
ZIP
11742
Mailing
25 CORPORATE DRIVE, HOLTSVILLE, NY 11742
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423450
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.23 C01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 18, 2012
Abate by
Jul 19, 2012
Penalty
Initial $4,900 · Current $3,000 Reduced
1910.23(c)(1)(i) Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing.    a) Mid-warehouse, storage racks  Employees were accessing and standing on the top of storage racks approximately 10 feet in height. Top of the racks acted as work platform(s) and were not guarded by a standard railing, or about, 3/5/12.      Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4900

1910.23 E01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2012
Abate by
Aug 8, 2012
Penalty
Initial $2,800 · Current $0 Reduced
1910.23(e)(1) A standard railing did not consist of top rail having a vertical height of 42 inches nominal from upper surface of top rail to floor.    a) Warehouse, Mezzanine  Employees were accessing the mezzanine storage area. The top of the mezzanine guardrail measured at approximately 36 inches above floor level on, or about, 3/5/12.      Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.101 B

Serious Gravity 5 1 instance 30 exposed
Issued
Jul 18, 2012
Abate by
Jul 19, 2012
Penalty
Initial $3,500 · Current $0 Reduced
1910.101(b) "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders was not in accordance with Compressed Gas Association Pamphlet P-1-1965.     a) Workplace; outdoor, compressed gas storage area - Liquid oxygen cylinder were stored on an inclined loading ramp, within 3 feet to vehicles on, or about, 3/5/12.      Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.134 C02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 18, 2012
Abate by
Jul 25, 2012
Penalty
Initial $2,100 · Current $0 Reduced
1910.134(2)(i) Respirator users were not provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible.    a) Warehouse Area  Employee whose duty required periodic cleaning of medical equipment was allowed to use a Half Face Piece  Dynarex 2203, Molded Surgical Masks, without being provided with information contained in Appendix D; on, or about, 3/5/12/.      Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2012
Abate by
Jul 19, 2012
Penalty
Initial $3,500 · Current $2,000 Reduced
1910.305(b)(2)(i) Junction boxes, and fittings were not provided with covers identified for the purpose.     a) Warehouse, near rolling door - Junction box was not protected by a cover on, or about, 3/5/12.      Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.