Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: ABC DISTRIBUTION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ABC DISTRIBUTION in 1 ACORN DRIVE, OAKWOOD VILLAGE, OH 44146 (NAICS 336211). OSHA activity number 332791953.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ABC Distribution for free Get an email when a new federal OSHA severe-injury report for ABC Distribution is published. One employer, no account, unsubscribe in one click.
Establishment
ABC DISTRIBUTION
Site address
1 ACORN DRIVE
City
OAKWOOD VILLAGE
State
OH
ZIP
44146
Mailing
1 ACORN DRIVE, OAKWOOD VILLAGE, OH 44146
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336211
Employees
40
Ownership type
Private (A)

7 citations on file for this inspection.

1910.157 G02

Serious Gravity 1 1 instance 40 exposed
Issued
May 29, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.157(g)(2):     29 CFR 1910.157(g)(2):  The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    Fire training has not been done on the site for approximately 5 years.
Recent events (3)
  • · F (S) $1620
  • · C (S) $2700
  • · Z (S) $2700

1910.213 H01

Serious Gravity 5 1 instance 10 exposed
Issued
May 29, 2012
Abate by
Jun 13, 2012
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.213(h)(1):     The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:    The Porter-Cable saw located adjacent to the truck roof scaffold had a guard which was stuck in the retracted position; the blade was exposed and did not stay in contact with the stock being cut.
Recent events (3)
  • · F (S) $2700
  • · C (S) $4500
  • · Z (S) $4500

1910.215 B09

Serious Gravity 5 1 instance 10 exposed
Issued
May 29, 2012
Abate by
Jun 3, 2012
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.215(b)(9):     Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    A Milwaukee bench grinder located on pillar 12 in the welding department did not have a tongue guard.
Recent events (3)
  • · F (S) $2160
  • · C (S) $3600
  • · Z (S) $3600

1910.252 B02 III

Serious Gravity 5 1 instance 10 exposed
Issued
May 29, 2012
Abate by
Jun 13, 2012
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.252(b)(2)(iii):     Worker(s) or other person(s) adjacent to welding area(s) were not be protected from the welding rays by noncombustible or flameproof screens or shields:    Welding screens were not provided between work stations where welding is done in the main building.
Recent events (3)
  • · F (S) $2700
  • · C (S) $4500
  • · Z (S) $4500

1910.134 C02 I

Other-than-serious 1 instance 10 exposed
Issued
May 29, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i):     Respirator users were not provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible:    The employee who cut fiberglass reinforced panels with a power saw was provided a respirator; he was not given the information in the Appendix prior to using the respirator.
Recent events (4)
  • · F (O) $0
  • · F (O) $0
  • · C (O) $0

1910.157 E02

Other-than-serious 1 instance 40 exposed
Issued
May 29, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2):     Portable fire extinguishers were not visually inspected at least monthly:    Fire extinguishers on the site were inspected on an annual basis; no monthly inspection was provided.
Recent events (4)
  • · F (O) $0
  • · F (O) $0
  • · C (O) $0

1910.1200 H03 II

Other-than-serious 1 instance 10 exposed
Issued
May 29, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(ii):     Employee training did not include the physical and health hazards of the chemicals in the work area:                The employee who cut fiberglass reinforced panels with a power saw was not trained in the hazards of the fiberglass dust.
Recent events (4)
  • · F (O) $0
  • · F (O) $0
  • · C (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332791953.