Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLEN OAK LUMBER & MILLING, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GLEN OAK LUMBER & MILLING, INC. in N2885 COUNTY F, MONTELLO, WI 53949 (NAICS 321912). OSHA activity number 332792993.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Glen OAK Lumber & Milling, INC. — free Get an email when a new federal OSHA severe-injury report for Glen OAK Lumber & Milling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N2885 COUNTY F
City
MONTELLO
State
WI
ZIP
53949
Mailing
N2885 COUNTY F, MONTELLO, WI 53949
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321912
Employees
120
Ownership type
A

12 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 120 exposed
Issued
May 8, 2012
Abate by
May 18, 2012
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a)    Boiler room housekeeping was poor with access to the emergency eye wash and fire extinguisher blocked.    b)    Dust system housekeeping was poor by the interlocked door.    c)    Dust system housekeeping was poor for the catwalk used for loading trailers.      Abatement Documentation and Abatement Certification Required.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.213 A09

Serious Gravity 5 5 instances 10 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.213(a)(9):     All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219:    a)  Double E machine had a drive shaft that was not guarded, approximately 41" long.  1910.219 (c)92)(i) requires all exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform be protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting.    b)  Transfer chain had a 1-1/2" diameter shaft that projected out approximately 4" without a guard.  1910.219(c)(4)(i) requires unguarded projecting shaft end(s) present a smooth edge and end and not project more than one half the diameter of the shaft.    c)   Outfeed conveyor for Marine Johnson rip saw had an unguarded belt and pulley drive unit. 1910.219(d)(1) requires Pulley(s) with part(s) seven (7) feet or less from the floor or work platform be guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).    d)  Outfeed conveyor for Marine Johnson rip saw had an unguarded belt and pulley drive unit.  1910.219(e)(3)(i) requires vertical or inclined belt(s) be enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o).    f)  Heeseman infeed conveyor for sander had an exposed chain and sprocket approximately 1" from orange guard.  1910.219(f)(3) requires sprocket wheels and chains which are seven (7) feet or less above floors or platforms be enclosed.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.213 H01

Serious Gravity 10 1 instance 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1910.213(h)(1):     The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material:    a)    DeWalt 7730 radial arm saw with Power Shop 250 guard had one of the lower blade guards stuck in the up position at the time of the inspection.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $4410
  • — Z (S) $6300

1910.213 I01

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.213(i)(1):     Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:    a)    Band saw wheels were not fully encased on Kimwood Ferrari resaw machine.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 N01

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.213(n)(1):     Metal guard(s) covering the cutting head(s), and saw(s) if used, were not provided on molding machine(s):    a)    Weinig molding machine had gaps in guarding for molding heads approximately 7" from frame.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.213 N03

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.213(n)(3):     Hood(s) or suitable guard(s) were not provided to prevent the hands of the operator from coming in contact with the inrunning rolls of feed rolls on molding machines:    a)    Weinig Molding machine had exposed feed rolls approximately 7" from frame.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 P04

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.213(p)(4):     Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:    a)    Belt sanders had unguarded nip points in plant #1.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.253 B04 III

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
May 9, 2012
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a)    Oxygen and acetylene tanks were stored together in Maintenance East.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.334 C02

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.334(c)(1):     Unqualified persons performed testing work on electric circuits or equipment.    a)    Maintenance employee who was not qualified was performing electrical testing without personal protective equipment or insulated tools.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i):     Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:    a)    Maintenance employee who was not qualified was performing electrical testing without personal protective equipment or insulated tools.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A06

Other-than-serious 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6):     The employer did not ensure that all nameplates or markings were not maintained in a legible condition:    a)    Caterpillar lift truck did not have a legible name plate beside the drivers seat.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.184 I01

Other-than-serious 1 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(1):     Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:    a)    Nylon sling hanging in plant #3 did not have a legible tag to identify capacity.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Glen OAK Lumber & Milling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332792993.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.