OSHA Inspection: BCI ACRYLIC BATH SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BCI ACRYLIC BATH SYSTEMS, INC. in 524 SOUTH HICKS ROAD, PALATINE, IL 60067 (NAICS 326191). OSHA activity number 332795277.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BCI Acrylic Bath Systems, INC. for free Get an email when a new federal OSHA severe-injury report for BCI Acrylic Bath Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
524 SOUTH HICKS ROAD
City
PALATINE
State
IL
ZIP
60067
Mailing
524 SOUTH HICKS ROAD, PALATINE, IL 60067
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326191
Employees
40
Ownership type
A

8 citations on file for this inspection.

1910.134 E01

Serious Gravity 10 2 exposed
Issued
Mar 16, 2012
Abate by
Apr 13, 2012
Penalty
Initial $4,900 · Current $2,500 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) Spray Booth -  The employer did not provide a medical evaluation for employees who are required to wear 3M tight fitting face respirators.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $4900

1910.134 F02

Serious Gravity 5 2 exposed
Issued
Mar 16, 2012
Abate by
Apr 13, 2012
Penalty
Initial $3,500 · Current $1,850 Reduced
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter    (a) Spray Booth -  The employer did not provide fit testing for employees who are required to wear 3M tight fitting face respirators.
Recent events (2)
  • · I (S) $1850
  • · Z (S) $3500

1910.147 C01

Serious Gravity 5 1 exposed
Issued
Mar 16, 2012
Abate by
Apr 6, 2012
Penalty
Initial $3,500 · Current $1,850 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a)  Facility Wide - The employer failed to establish and utilize energy control program consisting of control procedure(s), employee training, and periodic inspections.
Recent events (2)
  • · I (S) $1850
  • · Z (S) $3500

1910.212 A01

Serious Gravity 5 1 exposed
Issued
Mar 16, 2012
Abate by
Apr 27, 2012
Penalty
Initial $3,500 · Current $1,850 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Production Area -  The CNC machine was not equipped with guards to protect employees from rotating and moving parts.    (b)Tool Room- The vertical band saw was not equipped with enclosure guards for the unused portion of the blade(s).
Recent events (2)
  • · I (S) $1850
  • · Z (S) $3500

1910.242 B

Serious Gravity 5 1 exposed
Issued
Mar 16, 2012
Abate by
Mar 30, 2012
Penalty
Initial $4,200 · Current $2,200 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      (a) Production Area - All compressed air hoses used for cleaning purposes were not reduced to less than 30 psi.
Recent events (2)
  • · I (S) $2200
  • · Z (S) $4200

1910.303 B02

Serious Gravity 1 1 exposed
Issued
Mar 16, 2012
Abate by
Mar 30, 2012
Penalty
Initial $2,100 · Current $1,150 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      (a) Production Area - The power strip used to power the Nicrom wire table was not used in accordance with their listing or labeling electrical equipment.     (b) Production Area - The power strip used to power the hand tools was not used in accordance with their listing or labeling electrical equipment.
Recent events (2)
  • · I (S) $1150
  • · Z (S) $2100

1910.22 A01

Other-than-serious 1 exposed
Issued
Mar 16, 2012
Abate by
Mar 23, 2012
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.      (a) Tool Shop - The employer did not maintain clean floors allowing wood dust accumulation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $700

1910.334 A02 I

Other-than-serious 1 exposed
Issued
Mar 16, 2012
Abate by
Mar 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):      (a) Production Area - The Dewalt power Jig Saw located in the production area was observed to have a frayed cord.
Recent events (1)
  • · Z (O) $0

View BCI Acrylic Bath Systems, INC.'s full OSHA safety record →