HOLMESVILLE, OH ·
OSHA Inspection: ROTO SOLUTIONS, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of ROTO SOLUTIONS, INC. in 8300 COUNTY ROAD 189, HOLMESVILLE, OH 44633 (NAICS 326199). OSHA activity number 332795467.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROTO SOLUTIONS, INC.
- Site address
- 8300 COUNTY ROAD 189
- City
- HOLMESVILLE
- State
- OH
- ZIP
- 44633
- Mailing
- P.O. BOX 100, HOLMESVILLE, OH 44633
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 21
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.157 C04
- Issued
- Mar 12, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $1,980 · Current $990 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use: a. In the staging area at column B24, the fire extinguisher was not kept in its designated place.
Recent events (3)
- · R (S) $990
- · C (S) $1980
- · Z (S) $1980
1910.335 A01 II
- Issued
- Mar 12, 2012
- Abate by
- Apr 11, 2012
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment shall be maintained in a safe, reliable condition and shall be periodically inspected or tested, as required by 1910.137: a. At the workplace, the employer did not ensure that the Salisbury rubber insulating gloves Class 2, Type 1, had been electrically tested within the previous 12 months before first issue. b. At the workplace, the employer did not ensure that the Salisbury rubber insulating gloves Class 2, Type 1, received an air test along with the visual inspection for damage prior to each use.
Recent events (3)
- · R (S) $1650
- · C (S) $3300
- · Z (S) $3300
1910.242 B
- Issued
- Mar 12, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $3,960 · Current $990 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: a. In the quality area, the Coilhose compressed air nozzle used for cleaning purposes, such as blowing off plastic post covers, exceeded 30 psi. ROTO SOLUTIONS, INC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.242(b), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314590712 (OIS NUMBER 60757), CITATION NUMBER 1, ITEM NUMBER 10, AND WAS AFFIRMED AS A FINAL ORDER ON MARCH 24, 2011, WITH RESPECT TO A WORKPLACE LOCATED AT 8300 COUNTY ROAD 189, HOLMESVILLE, OHIO 44633.
Recent events (3)
- · R (S) $990
- · C (R) $3960
- · Z (R) $3960
More inspections at Roto Solutions, INC.
View Roto Solutions, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332795467.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.