Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LAWE INDUSTRIES

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of LAWE INDUSTRIES in 3994 EAST HWY. 290 WEST, DRIPPING SPRINGS, TX 78620 (NAICS 811191). OSHA activity number 332799543.

Watch Lawe Industries — free Get an email when a new federal OSHA severe-injury report for Lawe Industries is published. One employer, no account, unsubscribe in one click.
Establishment
LAWE INDUSTRIES
Site address
3994 EAST HWY. 290 WEST
City
DRIPPING SPRINGS
State
TX
ZIP
78620
Mailing
24165 WEST SUITTE #267, SAN ANTONIO, TX 78255
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811191
Employees
3
Ownership type
A

12 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $1500.00 Reduced
29 CFR 1910.22(a)(2):   The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition.   On or about February 17, 2012, employees were sliipping and sliding on the ramps in front of the open pits in bays #1 and #2 where an oily residue has accumulated from employees handling vehicle lubricants. The employer does not maintain the floor by providing material to remove the sippery film, exposing employees to the hazard of slips/trips and falls.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the floor is treated to remove the slippery film of oil.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.22 C

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(c):   "Covers and guardrails." Covers and/or guardrails were not provided to protect personnel from thehazards of open pits, tanks, vats, ditches, etc.  On or about February 17, 2012, employees changing oil in vehicles are required to walk around unattended open pits in bays #1 and #2 that are not equipped with covers or guardrails, exposing the employees to a fall hazard.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all open pits are covered or guardrails are provided.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 A

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1500.00 Reduced
29 CFR 1910.132(a):   Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.  On or about February 17, 2012, employees are required to perform general maintenance on vehicles that include, but are not limited to changing oil and servicing batteries without the employer providing eye protection, exposing the employees to the hazard of being splashed in the eyes by cleaners and vehicle fluids.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that eye protection is provided and utilized by employees changing oil, utilizing cleaners and performing other general vehicle maintenance.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $1800

1910.132 D01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1):   The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitated the use of personal protective equipment (PPE).  On or about February 17, 2012, employees were servicing and maintaining vehicles in the facility without the employer conducting a hazard assessment, exposing the employees to hazards such as, but not limited to electrical shock and slips/trips and falls.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a hazard assessment is conducted for all work employee's are required to perform for the company.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.141 D02 II

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $0.00 Reduced
29 CFR 1910.141(d)(2)(ii):   Each lavatory was not provided with hot and cold running water, or tepid runningwater.  On or about February 17, 2012, employees are performing vehicle maintenance and utilizing the restroom without the employer providing hot or tepid water, exposing the employees to unsanitary conditions.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees have hot or tepid water to clean their hands properly after utilizing the restroom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1800

1910.151 C

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.151(c):  Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.[63 FR 33450, June 18, 1998]  On or about February 17, 2012, employees are required to service batteries and utilize cleaning agents without the employer providoing a suitable eye wash and body wash facility, exposing the employees to the hazard of contacting corrosive materials.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a suitable facility is installed for employees to flush their eyes and body during an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.157 C04

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1500.00 Reduced
29 CFR 1910.157(c)(4):   The employer did not ensure that portable fire extinguishers were maintained in a fully charged and operable condition and kept in their designated places at all times except during use.   On or about February 17, 2012, employees were performing servicing and maintenance duties in bays #1 and #2 while two of the four fire extinguishers were not fully charged, exposing the employees to the hazard of being engulfed by fires.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all fire extinguishers are fully charged for employees to fight incipient stage fires.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $1800

1910.157 E03

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3):   Portable fire extinguishers were not subjected to an annual maintenance check:  On or about February 17, 2012, employees were performing servicing and maintenance duties in bays #1 and #2 without fire extinguishers in the facility being inspected, exposing employees to the hazard of being engulfed by fires.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all fire extinguishers are subjected to an annual inspection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1500.00 Reduced
29 CFR 1910.303(f)(2):   Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about February 17, 2012, employees are required to switch breakers in the panel on and off to control the air compressor and lights where there are open holes in the panel, exposing employees to an electrical shock hazard.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that there are no open holes on breaker panels.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $1800

1910.305 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii):   Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about February 17, 2012, employees were opening the breaker box and flipping the breaker on and off that controls the air compressor where there were holes not covered on the panel, exposing the employees to an electrical shock hazard.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all unused openings in breaker boxes are effectively closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1000.00 Reduced
29 CFR 1910.1200(e)(1):   The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about February 17, 2012, employees were required to work with hazardous chemicals in the workplace without the employer developing a hazard communication program, exposing the employees to hazards such as, but not limited to inhalation and burns.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a hazard communication program is developed and made available to employees working with hazardous chemicals.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1800

1910.1200 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1):   The employer did not have a material safety data sheet for each hazardous chemical which they used:  On or about February 17, 2012, employees were working with various lubricants and cleaners to perform automotive servicing and maintenance activities without the employer providing material safety data sheets for each hazardous chemical they used, exposing the employees to the hazard of contacting hazardous chemicals.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure material safety data sheets are provided for each hazardous chemical that employees are using.