Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: EDWARDS AIR FORCE BASE CIVIL ENGINEERING

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EDWARDS AIR FORCE BASE CIVIL ENGINEERING in BLDG. 8451 10 E. SATURN BLVD., EDWARDS AFB, CA 93524 (NAICS 928110). OSHA activity number 332801141.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Edwards AIR Force Base Civil Engineering for free Get an email when a new federal OSHA severe-injury report for Edwards AIR Force Base Civil Engineering is published. One employer, no account, unsubscribe in one click.
Site address
BLDG. 8451 10 E. SATURN BLVD.
City
EDWARDS AFB
State
CA
ZIP
93524
Mailing
95 ABW/CC 5 SELLARS AVENUE, EDWARDS AFB, CA 93524
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
20
Ownership type
Federal government (D)

5 citations on file for this inspection.

1910.106 D04 IV

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 31, 2012
Abate by
Sep 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(4)(iv): An inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system that was designed to provide for a complete change of air within the room at least six times per hour:    a) In Room 60 - On or about 3/7/12, the exhaust ventilation for the flammable storage room was capped in the penthouse.    b) In Room 80 - On or about 3/7/12, the exhaust ventilation for the flammable storage room was non-functional.
Recent events (1)
  • · Z (S) $0

1910.141 A05

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 31, 2012
Abate by
Sep 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(5): Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin:    (a) Access areas above Rooms 71, 64, 91, and 67 - On or about 6/21/12, the workplace was not maintained to prevent the entrance or harborage of rodents.
Recent events (1)
  • · Z (S) $0

1910.1450 E03 III

Serious Gravity 5 4 instances 5 exposed
Issued
Aug 31, 2012
Abate by
Sep 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1450(e)(3)(iii): The employer's Chemical Hygiene Plan did not include a requirement that fume hoods and other protective equipment functioned properly and/or did not include specific measures that would be taken to ensure proper and adequate performance of such equipment:    a) In Room 71, Lab hood 8451-71B - On or about 3/7/12, the laboratory hood did not have an average face velocity of at least 80 fpm.     b) In Room 67- On or about 3/7/12, room air was not balanced so as to prevent attic air re-entrainment.    c) On the Roof - On or about 6/21/12, the discharge stacks were not at least 10 feet above the highest roof level.     d) At Bldg. 8451 - On or about 3/7/12, an air balancing study was not performed following installation of new air handling units to ensure that the hoods and the ventilation system were functioning correctly.
Recent events (1)
  • · Z (S) $0

1910.1001 J03 I

Other-than-serious 1 instance 5 exposed
Issued
Aug 31, 2012
Abate by
Sep 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(j)(3)(i): Warning signs were not provided and displayed at each regulated area. Warning signs were not posted at all approaches to the regulated area so that an employee could read the signs and could take necessary protective steps before entering the area:    a) In the Penthouse - On or about 3/7/12, warning signs were not posted at the entrance, and were not provided and displayed at each regulated area.
Recent events (1)
  • · Z (O) $0

1910.1001 K01

Other-than-serious 1 instance 5 exposed
Issued
Aug 31, 2012
Abate by
Sep 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(k)(1): The employer did not maintain all surfaces as free as practicable of ACM waste and/or debris and accompanying dust:    a) In the Penthouse - On or about 3/7/12, surfaces were not maintained as free as practicable of ACM waste and debris
Recent events (1)
  • · Z (O) $0

View Edwards AIR Force Base Civil Engineering's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332801141.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.