Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: CORPORATE INSTALLATION SPECIALISTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CORPORATE INSTALLATION SPECIALISTS, LLC in 18667 SHELDON RD., MIDDLEBURG HEIGHTS, OH 44130 (NAICS 423210). OSHA activity number 332801489.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corporate Installation Specialists, LLC for free Get an email when a new federal OSHA severe-injury report for Corporate Installation Specialists, LLC is published. One employer, no account, unsubscribe in one click.
Site address
18667 SHELDON RD.
City
MIDDLEBURG HEIGHTS
State
OH
ZIP
44130
Mailing
18667 SHELDON RD., MIDDLEBURG HEIGHTS, OH 44130
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423210
Employees
20
Ownership type
Private (A)

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 20 exposed
Issued
Jun 8, 2012
Abate by
Jun 28, 2012
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.        On and before 02/22/2012 office furniture and miscellaneous product and debris cluttered the walkway and/or aisle way of the warehouse area.
Recent events (2)
  • · I (S) $1080
  • · Z (S) $1800

1910.36 D01

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 8, 2012
Abate by
Jun 28, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.36(d)(1):  Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:      On and before 02/22/2012 the exit door, located in the main warehouse area was secured by a chain and lock. The secured exit is the primary door used by employees who work in the area, and has the potential to delay employee access to the exit discharge in the event of a fire or other emergency.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.178 L01 I

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 8, 2012
Abate by
Jul 23, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l)    As of 02/22/2012, the employer failed to establish a powered industrial vehicle (PIV) training program at the site, which would have ensured that employees were trained to the level of competency needed to safely operate the company's fork truck.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.1200 E01

Serious Gravity 1 1 instance 20 exposed
Issued
Jun 8, 2012
Abate by
Jul 30, 2012
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:       The company did not develop, implement, or maintain a written hazard communication program at the facility. Chemicals used at the facility include, but are not limited to, flooring glue, acid batteries, cleaning solvents (etc.).
Recent events (2)
  • · I (S) $1080
  • · Z (S) $1800

1910.1200 H

Serious Gravity 1 1 instance 20 exposed
Issued
Jun 8, 2012
Abate by
Jul 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and 2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into the workplace:        Hazard communication training was not completed for employees who utilized chemicals at the facility. Chemicals used at the facility include, but are not limited to, flooring glue, acid batteries, cleaning solvents (etc.).
Recent events (2)