OSHA Inspection: FLEXIBLE FOAM PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLEXIBLE FOAM PRODUCTS, INC. in 13801 KOLTER RD, SPENCERVILLE, OH 45887 (NAICS 811111). OSHA activity number 332802271.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flexible Foam Products, INC. — free Get an email when a new federal OSHA severe-injury report for Flexible Foam Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13801 KOLTER RD
City
SPENCERVILLE
State
OH
ZIP
45887
Mailing
200 E. NORTH ST., SPENCERVILLE, OH 45887
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
2
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    a) Flexible Foam Products, Inc. - Spencerville, Ohio: On or about March 12, 2012, the employer did not assure that employees were protected from fall hazards of approximately 13-feet when accessing the top of truck trailers.  A standard guardrail, or equivalent protection, was not provided to employees that accessed the trailers to conduct repairs.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $3,300 · Current $1,650 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose:    a) Flexible Foam Products, Inc. - Spencerville, Ohio: On or about March 12, 2012, the employer did not assure that a junction box, located on the ceiling in the tool crib was provided with a cover, exposing employees to electrical shock hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1650
  • — Z (S) $3300

1910.305 J01 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:    a) Flexible Foam Products, Inc. - Spencerville, Ohio: On or about March 12, 2012, the employer did not assure that light fixtures in the tool crib were installed so that live parts were not exposed.  Employees that obtained parts from the shelves in the tool crib were exposed to electrical hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Other-than-serious 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 5010

29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:    a) Flexible Foam Products, Inc. - Spencerville, Ohio: On or about March 9, 2012, the employer did not assure employees were provided with a material data sheet for KOI Hydraulic Oil and SAE 5W30 Motor Oil used in the maintenance area, which would warn employees of potential health effects such as, but not limited to eye and skin irritation.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Flexible Foam Products, INC.'s full OSHA safety record →