Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-31

OSHA Inspection: BENEFIEL PROFESSIONAL PLUMBING, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BENEFIEL PROFESSIONAL PLUMBING, INC in 3003 E. KELLOGG, WICHITA, KS 67211 (NAICS 238220). OSHA activity number 332802784.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benefiel Professional Plumbing, INC — free Get an email when a new federal OSHA severe-injury report for Benefiel Professional Plumbing, INC is published. One employer, no account, unsubscribe in one click.
Site address
3003 E. KELLOGG
City
WICHITA
State
KS
ZIP
67211
Mailing
711 N MT CARMEL, WICHITA, KS 67203
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.21 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,800 · Current $450 Reduced
29 CFR 1926.21(b)(2):  The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.    Employees installing a sewer pipe in an excavation approximately 7' deep located at 3003 E. Kellogg, Wichita, KS 67211 were not trained on how to protect themselves from cave-in hazards including use of protective systems and inspection of soil conditions.
Recent events (2)
  • — I (S) $450
  • — Z (S) $1800

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,800 · Current $450 Reduced
29 CFR 1926.100(a):  Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.    Employees installing a sewer pipe in an excavation located at 3003 E. Kellogg, Wichita, KS 67211 were exposed to head injury hazards from impact with the excavator bucket, and from objects falling into the excavation including but not limited to tools, pipes and excavated material in that; hard hats were not worn by employees working in the excavation.
Recent events (2)
  • — I (S) $450
  • — Z (S) $1800

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $3,000 · Current $750 Reduced
29 CFR 1926.651(k)(1):  Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.    Employees installing a sewer pipe in an excavation approximately 7' deep located at 3003 E Kellogg, Wichita, KS 67211 were exposed to struck-by and cave-in hazards in that; a competent person did not conduct an inspection of the excavation for soil conditions and the use of appropriate protective systems.
Recent events (2)
  • — I (S) $750
  • — Z (S) $3000

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $3,000 · Current $750 Reduced
29 CFR 1926.651(j)(2):  Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    Employees installing a sewer pipe in an excavation approximately 7' deep located at 3003 E Kellogg, Wichita, KS 67211 were exposed to struck-by hazards in that; the spoil pile, materials and equipment was not kept at least 2' back from the edge of the excavation.
Recent events (2)
  • — I (S) $750
  • — Z (S) $3000

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $4,200 · Current $1,050 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:    Employees installing a sewer pipe in an excavation approximately 7' deep located at 3003 E Kellogg, Wichita, KS 67211 were exposed to struck-by and cave-in hazards in that; adequate protective systems for Class B soil such as but not limited to shoring, shielding, sloping and or benching in accordance with paragraph (b) or (c) was not utilized.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $4200

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,800 · Current $450 Reduced
29 CFR 1926.1053(b)(1):  When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    Employees working at the jobsite located at 3003 E Kellogg, Wichita, KS 67211 were exposed to fall hazards in that the ladder used to access the excavation did not extend at least 3' above the upper landing surface.
Recent events (2)
  • — I (S) $450
  • — Z (S) $1800

1926.1053 B04

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4):  Ladders shall be used only for the purpose for which they were designed.    Employees working at the jobsite located at 3003 E Kellogg, Wichita, KS 67211 were exposed to fall hazards in that; a step ladder was leaned against the wall of the excavation for access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332802784.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.