NEOSHO, MO —
OSHA Inspection: MISSOURI WALNUT
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MISSOURI WALNUT in 11417 OAK ROAD, NEOSHO, MO 64850 (NAICS 321113). OSHA activity number 332804012.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MISSOURI WALNUT
- Site address
- 11417 OAK ROAD
- City
- NEOSHO
- State
- MO
- ZIP
- 64850
- Mailing
- 11417 OAK ROAD, NEOSHO, MO 64850
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 111
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.37 B04
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: (a) Exits and exit routes were not clearly marked.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.145 C03
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): (a) A safety sign showing warning of the fall hazard was not placed on the plastic chain hanging in front of an overhead door located on an upper floor in the power house. (b) Signs expressing danger did not explain what the danger was and did not include universal graphics to be understood by non English speaking employees in the Stacker area where most of the employees did not read or speak English. (c) Exit signs were not present in the warehouse.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 A03 I
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: (a) Surfaces in the dry line building, including floors, were not kept free of the accumulation of dust.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.147 C04 I
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Procedures were not developed and implemented for workers cleaning in and under the Corley Sawmill End Trimer saw; (b) Procedures were not developed and implemented for workers cleaning in and under the chains pre and post of the Corley Sawmill End Trimer saw.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.147 C07 I A
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) Workers authorized to work in and under the Corley Sawmill End Trim saw did not receive training in the recognition of applicable hazardous energy, the magnitude of the energy available, and the methods and means necessary for energy isolation; (b Workers authorized to work in and under the automated chains pre and post of the Corley Sawmill End Trim saw did not receive training in the recognition of applicable hazardous energy, the magnitude of the energy available, and the methods and means necessary for energy isolation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $3,600 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) The operator of a Toyota #29 powered industrial fork truck did not remove the truck from service when the operator observed that two lights were not working.
Recent events (2)
- — I (S) $1440
- — Z (S) $3600
1910.178 Q01
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: (a) The flashing light on the #29 Toyota forked lift did not work, and the fork lift was not removed from service until repairs were made. (b) The rear light on the #29 Toyota forked lift did not work, and the fork lift was not removed from service until repairs were made.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 B04
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.213(b)(4): Power controls and operating controls were not located within easy reach of the operator while he was at his regular work location, making it necessary for him to reach over the cutter to make adjustments (a) The dry line pre sorting chain line had controls on stands at each end, placing the controls out of reach of workers on the chain line. Emergency stop controls were not available on the line.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.219 C04 I
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) On the transfer belt in the dry line building a projecting end of a shaft projected 3 inches and was 1.5 inches in diameter; (b) On the transfer belt in the dry line building a projecting end of a shaft projected 2.625 inches and was 1.375 inches in diameter.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.219 F03
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) Sprocket wheels and chains located at the start of the Dry Line by the lathe drop were not guarded; (b) Sprocket wheels and chains located at the start of the Stacker were not adequately guarded; (c) Sprocket wheels and chains located at the stacking end of the Stacker were not adequately guarded.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.303 B01
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $6,300 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): (a) Conduit running under the conveyor system in the dry line building near the rip saw was not anchored to prevent movement and damage. The conduit had come apart leaving the wires exposed to damage, and did not provide the protection required by (ii) and (viii); (b) Conduit running outside below the debarker was not adequately supported and not located to prevent being struck and damaged. The conduit had come apart and cut into the wires exposing the copper to the environment. The conduit had been struck and bent in more than one location, and did not provide the protection required by (ii) and (viii); (c) Conduit going to the refrigerator in the break room had seperated exposing the wires to damage, and did not provide the protection required by (ii) and (viii); (d) Seal tite lines were 15 feet in length, longer than the 6' allowed by the National Electrical Code. The added length created pressure on the 90 degree connect causing the seal tite to seperate and exposing the wiring to damage, and did not provide the protection required by (ii) and (viii);
Recent events (2)
- — I (S) $2520
- — Z (S) $6300
1910.305 B01 II
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $4,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) The panel box cabinet in the dry line building had an opening on the side that was not closed; (b) The 450V box near the head saw had an opening 2" in diameter that was not closed; (c) A control box in Saw Mill #3 had a knockout missing and was not closed.
Recent events (2)
- — I (S) $1800
- — Z (S) $4500
1910.305 B02
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $6,300 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) The switch outlet in the foreman's office at entrance from outside did not have a cover or faceplate; (b) The duplex outlet box in the non smoking break room to the left of the sink and 3 feet from the sink did not have a cover or faceplate.
Recent events (2)
- — I (S) $2520
- — Z (S) $6300
1910.1000 C
- Issued
- Jun 8, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $5,400 · Current $2,160 Reduced
General-duty citation text
29 CFR 1910.1000(c): An employee(s) was exposed to respirable dust in excess of the 8-hour time weighted average limits of 5mg/m3 listed in Table Z-3: Los empleados estuvieron expuestos a materiales en exceso del TWA de ocho horas listado para ese material en la Tabla Z-3 de la subparte Z de 29 CFR parte 1910 (a) A employee was exposed to respirable dust at 6.1 mg/m3 with an SAE of 0.084.
Recent events (2)
- — I (S) $2160
- — Z (S) $5400
1910.253 B02 II
- Issued
- Jun 8, 2012
- Abate by
- Jul 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: (a): In the shop oxygen bottles were not stored in a manner to prevent bottles from falling over if it.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Missouri Walnut
View Missouri Walnut's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332804012.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.