OSHA Inspection: WAGNER TRANSPORTATION COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WAGNER TRANSPORTATION COMPANY in 410 NORTH LOCUST STREET, TWIN FALLS, ID 83303 (NAICS 484230). OSHA activity number 332804772.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wagner Transportation Company — free Get an email when a new federal OSHA severe-injury report for Wagner Transportation Company is published. One employer, no account, unsubscribe in one click.
Site address
410 NORTH LOCUST STREET
City
TWIN FALLS
State
ID
ZIP
83303
Mailing
BOX 192, TWIN FALLS, ID 83303
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484230
Employees
19
Ownership type
A

6 citations on file for this inspection.

1910.215 A04

Serious Gravity 1 1 instance 7 exposed
Issued
Jun 8, 2012
Penalty
Initial $1,530 · Current $1,530
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a)  Repair Shop: On 03/08/12 and at time s prior thereto, a pedestal mounted grinder work rest for the right abrasive wheel was set to seven sixteenth (7/16) inch.    Note:  Abatement certification and documentation are NOT required for this item.
Recent events (1)
  • — Z (S) $1530

1910.215 B09

Serious Gravity 1 1 instance 7 exposed
Issued
Jun 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a)  Repair Shop:  On 03/08/2012, and at times prior thereto, the right wheel tongue guard was set to 7/16" on the grinder to the right of the Utility Co grinder.    (b)  Repair Shop: On 03/08/2012, and at times prior thereto, the tongue guard was missing on the Utility Co grinder serial # 808912.    Note: Abatement certification and documentation are NOT required for htis item.
Recent events (1)
  • — Z (S) $0

1910.178 L04 III

Other-than-serious 1 instance 7 exposed
Issued
Jun 8, 2012
Abate by
Jul 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years:    Site: On 03/08/2012 and at times prior thereto, the Powered Industrial Truck trainer was not evaluating performance as required.    NOTE: Abatement Certification IS required for this item.
Recent events (1)
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 6 exposed
Issued
Jun 8, 2012
Abate by
Jul 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required:    Site: On 03/08/2012, and at times prior thereto, the powered industrial truck trainer did not maintain a record of training conducted with each employee authorized to operate the forklifts.    Note: Abatement certification IS required for this item.
Recent events (1)
  • — Z (O) $0

1910.254 D09 III

Other-than-serious 2 instances 7 exposed
Issued
Jun 8, 2012
Abate by
Jul 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.254(d)(9)(iii): Cabled with damaged insulation or exposed bare conductors were not replaced:    Repair Shop: On 03/08/2012, and at times prior thereto, the ground lead of two Linde VI 252-C welders had cuts that exposed the conductor.    Note 1: Abatement certification IS required for this item.    Note 2: Work cables may be repaired under certain conditions.
Recent events (1)
  • — Z (O) $0

1910.305 A02 IX

Other-than-serious 7 exposed
Issued
Jun 8, 2012
Abate by
Jul 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard:    a)  Parts Room main floor:  On 03/08/2012, and at times prior thereto, unprotected and energized incandescent bulbs were located at heights from  6'7" to 6' 9" from the floor.    b)  Parts Room mezzanine: On 03/08/2012, and at times prior thereto, unprotected and energized incandescent bulbs were located at a height of 6' from the floor.    c)  Parts Warehouse Mezzanine: On 03/08/2012, and at times prior thereto, unprotected and energized flourescent bulbs were located at a height of 6' from the floor.    Note: Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $0

View Wagner Transportation Company's full OSHA safety record →