Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M & Z CONSTRUCTION CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of M & Z CONSTRUCTION CORP. in 339 HEATHCOTE RD, SCARSDALE, NY 10583 (NAICS 238170). OSHA activity number 332806371.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & Z Construction Corp. — free Get an email when a new federal OSHA severe-injury report for M & Z Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
339 HEATHCOTE RD
City
SCARSDALE
State
NY
ZIP
10583
Mailing
20 JAMES STREET, OSSINING, NY 10562
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 1 4 instances 4 exposed
Issued
May 18, 2012
Abate by
Jun 11, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.      On or about 3/9/2012, Job Site    a) The employees were installing exterior siding and not provided training as required by the standard.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
May 18, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.      On or about 3/9/2012, Job Site    a) The employee used an extension cord to energize his tool.  The extension cord had the ground pin broken off.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
May 18, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.    On or about 3/9/2012    a) The extension cord had the sheathing worn off.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
May 18, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    On or about 3/9/2012, Job Site    a) The two employees worked on the pump jack scaffold without fall protection. They were exposed to falling 17' to the ground below.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.454 A

Serious Gravity 10 4 instances 4 exposed
Issued
May 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:    On or about 3/9/2012, Job Site    a) The employees, who worked from a pump jack scaffold were not provided scaffold training as required by the standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace re-installed.    On or about 3/9/2012, Job Site    a) The employees worked from a pump jack scaffold that did not have the triangular bracing at the bottom.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332806371.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.