Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANUFACTURING SOLUTIONS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANUFACTURING SOLUTIONS INC in 2320 N OLIVER RD, NEWTON, KS 67114 (NAICS 332710). OSHA activity number 332807148.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manufacturing Solutions INC — free Get an email when a new federal OSHA severe-injury report for Manufacturing Solutions INC is published. One employer, no account, unsubscribe in one click.
Site address
2320 N OLIVER RD
City
NEWTON
State
KS
ZIP
67114
Mailing
2320 N OLIVER RD, NEWTON, KS 67114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
23
Ownership type
A

3 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 1 instance 2 exposed
Issued
May 16, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.213(c)(1):  Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Employees were utilizing a table saw to perform woodworking opertions with the guard removed. Employees were exposed to amputation hazards.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.242 B

Serious Gravity 5 2 instances 2 exposed
Issued
May 16, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i..  In the main shop employee were using compressed air guaged at approximately 125 psi for cleaning purposes.  Employees were exposed to air injection and foreign object hazards.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 16, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures:  In the main shop electrical wiring supplying power to the Farmham Roll macine was not contained in an approved electrical enclosure. Employees were exposed to a electrical shock hazards.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

View Manufacturing Solutions INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332807148.