NEWTON, KS —
OSHA Inspection: MANUFACTURING SOLUTIONS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANUFACTURING SOLUTIONS INC in 2320 N OLIVER RD, NEWTON, KS 67114 (NAICS 332710). OSHA activity number 332807148.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUFACTURING SOLUTIONS INC
- Site address
- 2320 N OLIVER RD
- City
- NEWTON
- State
- KS
- ZIP
- 67114
- Mailing
- 2320 N OLIVER RD, NEWTON, KS 67114
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 23
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.213 C01
- Issued
- May 16, 2012
- Abate by
- Jun 7, 2012
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Employees were utilizing a table saw to perform woodworking opertions with the guard removed. Employees were exposed to amputation hazards.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.242 B
- Issued
- May 16, 2012
- Abate by
- Jun 7, 2012
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.. In the main shop employee were using compressed air guaged at approximately 125 psi for cleaning purposes. Employees were exposed to air injection and foreign object hazards.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.303 G02 I
- Issued
- May 16, 2012
- Abate by
- Jun 7, 2012
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures: In the main shop electrical wiring supplying power to the Farmham Roll macine was not contained in an approved electrical enclosure. Employees were exposed to a electrical shock hazards.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
More inspections at Manufacturing Solutions INC
View Manufacturing Solutions INC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332807148.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.