COLUMBUS, OH —
OSHA Inspection: BLACK HAWK ROOF CO. OF FLORIDA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLACK HAWK ROOF CO. OF FLORIDA in 6800 EAST BROAD ST, COLUMBUS, OH 43213 (NAICS 238160). OSHA activity number 332808294.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BLACK HAWK ROOF CO. OF FLORIDA
- Site address
- 6800 EAST BROAD ST
- City
- COLUMBUS
- State
- OH
- ZIP
- 43213
- Mailing
- 544 PINELLAS BAYWAY SOUTH PENTHOUSE 4, TIERRA VERDE, FL 33715
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 16
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 F06
- Issued
- Apr 4, 2012
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent andcontinuous. a. On the roof where the employerused a Storm Responder portable generator to supply power to portable tools and equipment, one of the extension cords was missing a ground prong thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1926.501 B03
- Issued
- Apr 4, 2012
- Abate by
- Apr 11, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.501(b)(3): "Hoist areas." Each employee in a hoist area shall be protected from falling 6 feet (1.8 m) or moreto lower levels by guardrail systems or personal fall arrest systems. If guardrail systems, [or chain, gate, or guardrail] or portions thereof, areremoved to facilitate the hoisting operation (e.g., during landing of materials), and an employee must lean through the access opening or out over theedge of the access opening (to receive or guide equipment and materials, for example), that employee shall be protected from fall hazards by apersonal fall arrest system. a. On the southeast side of the roof where employees were off loading trash into a dumpster below the roof on the ground, the employer did not use a fall protection system such as guardrails or personel fall arrest systems therby exposing employees to a 30 foot fall hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.502 F01
- Issued
- Apr 4, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.502(f)(1): The warning line shall be erected around all sides of the roof work area. a. On the norht side of the building where employees were performing roof installation work, the employer did not install a warning line system to warn employees thereby exposing employeesto a fall hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.502 F01 I
- Issued
- Apr 4, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.502(f)(1)(i): When mechanical equipment is not being used, the warning line shall be erected not less than 6feet (1.8 m) from the roof edge. a. On the northeast side of the building where roofing work was performed, the employer installed the warning line at an angle and the warning line was located within one foot of the edge of the roof thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1926.502 F01 III
- Issued
- Apr 4, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, materials handling areas, storage areas, and hoisting areas shall beconnected to the work area by an access path formed by two warning lines. a. On the northwest side of the building where employees entered the roof to install roofing materials, the employer did not set up am access path to direct employees from the ladder access to the working area thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332808294.