OSHA Inspection: THE HOME DEPOT, INC. #1508

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE HOME DEPOT, INC. #1508 in 8477 S. YOSEMITE ST., LONE TREE, CO 80124 (NAICS 444110). OSHA activity number 332808823.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Home Depot, INC. #1508 for free Get an email when a new federal OSHA severe-injury report for The Home Depot, INC. #1508 is published. One employer, no account, unsubscribe in one click.
Site address
8477 S. YOSEMITE ST.
City
LONE TREE
State
CO
ZIP
80124
Mailing
8477 S. YOSEMITE ST., LONE TREE, CO 80124
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
120
Ownership type
Private (A)

8 citations on file for this inspection.

1910.305 G02 III

Repeat Gravity 1 3 instances 3 exposed
Issued
Jun 14, 2012
Abate by
Jun 19, 2012
Penalty
Initial $16,500 · Current $7,000 Reduced
29 CFR 1910.305(g)(2)(iii):  Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a)  On or about March 13, 2012, and at times prior, employees were exposed to shock and burn hazards from cords that had the insulation pulled back from plugs on the following peices of equipment:     1) order picker recharger plug on the EXIDE XI System Type G, Model G1-12-550, Serial Number UG29814, in the receiving area.  2) JLG Electric ladder 12SP, Serial Number 0900030026, hand marking "#0".  3) Tennant 5680 Zamboni (floor polisher) stored in the janitor's closet.     Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (R) $7000
  • · Z (R) $16500

1910.303 G01 II

Serious 3 instances 120 exposed
Issued
Jun 14, 2012
Abate by
Jun 19, 2012
Penalty
Initial $2,200 · Current $2,200
29 CFR 1910.303(g)(1)(ii):  The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a)  On or about March 13, 2012, and at times prior, items were stored in front of electrical boxes, panels and switches, inhibiting access in case of emergency in the following locations:  1)  the computer room on the south side of the building on west end,   2)  the offices on the north side of the store,  3)  the janitor's closet on the south side of the store.  4)  the electrical room on the south side of the building.      Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $2200
  • · Z (R) $2200

1910.22 A01

Other-than-serious 1 instance 20 exposed
Issued
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  (a)  On or about March 13, 2012, and at times prior, the south facing exit from the mill works area had insulating bags placed along length of the double doors on the floor exposing employees to trip hazards.
Recent events (1)
  • · Z (O) $0

1910.36 D01

Other-than-serious 1 instance 3 exposed
Issued
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  (a)  On or about March 13, 2012, and at times prior, the north facing exit door on the east end of the garden center was locked and blocked.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • · Z (O) $0

1910.36 G02

Other-than-serious 1 instance 3 exposed
Issued
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2):  Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a) On or about March 13, 2012, and at times prior, the exit route in the receiving area was not maintained a minimum of 28 inches wide in that pallets of incoming merchandise were placed such that they obstructed access to the emergency exit for the area.
Recent events (1)
  • · Z (O) $0

1910.305 J01 IV

Other-than-serious 1 instance 3 exposed
Issued
Jun 14, 2012
Abate by
Jun 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts:  (a)  On or about March 13, 2012, and at times prior, employees were exposed to shock and burn hazards from electrical boxes in the outdoor garden center that were open.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • · Z (O) $0

1910.1200 F05 I

Other-than-serious 1 instance 10 exposed
Issued
Jun 14, 2012
Abate by
Jun 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i):  The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  (a)  On or about March 13, 2012, and at times prior, a plastic spray bottle used by employees in the checkout area on the west end of the store was not labeled with the identity of the hazardous chemical.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • · Z (O) $0

1910.1200 F05 II

Other-than-serious 2 instances 16 exposed
Issued
Jun 14, 2012
Abate by
Jun 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii):  The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  (a)  On or about March 13, 2012, and at times prior, plastic spray bottles used by employees in the paint area and in the checkout area on the west end of the store, were not labeled with the warnings about the hazards of chemical that they contained.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • · Z (O) $0