WALLINGFORD, CT —
OSHA Inspection: NUCOR STEEL CONNECTICUT INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NUCOR STEEL CONNECTICUT INCORPORATED in 35 TOELLES ROAD, WALLINGFORD, CT 06492 (NAICS 331111). OSHA activity number 332810761.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NUCOR STEEL CONNECTICUT INCORPORATED
- Site address
- 35 TOELLES ROAD
- City
- WALLINGFORD
- State
- CT
- ZIP
- 06492
- Mailing
- 35 TOELLES ROAD, WALLINGFORD, CT 06492
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331111
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 16, 2012
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Roll Mill Area: The employer did not establish and implement step-by-step hazardous energy control lockout/tagout procedures in the site and machine specific for the employees during servicing, maintenence and other duties for the equipment, such as (but not limited to) the roller/passes contained within the roll stands.
Recent events (3)
- — F (U) $6300
- — C (S) $6300
- — Z (S) $6300
1910.147 C07 I A
- Issued
- Jul 16, 2012
- Abate by
- Jul 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. Roll Mill Area: Each authorized employee did not receive training in the recognition of hazardous energy sources, the type and magnitude of the energy and the methods and means necessary to isolate and de-energize the roll mill and roll stands during the grinding work on the roller/passes during the changeover process.
Recent events (3)
- — F (U) $0
- — C (S) $0
- — Z (S) $0
More inspections at Nucor Steel Connecticut Incorporated
View Nucor Steel Connecticut Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 331111)
More inspections in CT