Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: U.S. DEPARTMENT OF VETERAN AFFAIRS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF VETERAN AFFAIRS in 3350 LA JOLLA VILLAGE DRIVE, SAN DIEGO, CA 92161 (NAICS 622110). OSHA activity number 332811561.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Veteran Affairs for free Get an email when a new federal OSHA severe-injury report for U.S. Department of Veteran Affairs is published. One employer, no account, unsubscribe in one click.
Site address
3350 LA JOLLA VILLAGE DRIVE
City
SAN DIEGO
State
CA
ZIP
92161
Mailing
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
4400
Ownership type
Federal government (D)

8 citations on file for this inspection.

1910.178 A04

Serious Gravity 5 2 instances 2200 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation were performed by the customer or user without manufactures prior written approval. Capacity, operation, and maintenance instruction plates, tags or decals were not changed accordingly:    On March 13, 2012, and at times prior thereto, where six foot extensions and a boom attachment were used, the employer did not get the manufacturers approval to be used with the forklifts.
Recent events (1)
  • · Z (S) $0

1910.178 A05

Serious Gravity 5 2 instances 2200 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): Where powered industrial trucks were equipped with front-end attachments other than factory installed attachments, the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with the load laterally centered:    On March 13, 2012, and at times prior thereto, where six foot extensions and a boom attachment were used for the forklifts, the forklifts did not have a name plate to indicate the truck's lifting capacity.
Recent events (1)
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2012
Abate by
Apr 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect the operator(s) and other employees from hazard(s) created by rotating parts:    Building 2, Machine Shop: On March 13, 2012, and at times prior thereto, the rotating notched chuck on the Rockwell horizontal lathe was not provided with safeguarding to prevent unintentional contact.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 2200 exposed
Issued
Apr 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    Carpenter Shop: On March 13, 2012, and at times prior thereto, the Baldor bench grinder's adjustable tongue guard measured at one half inch from the abrasive wheel.
Recent events (1)
  • · Z (S) $0

1910.253 B04 I

Serious Gravity 5 1 instance 2200 exposed
Issued
Apr 24, 2012
Abate by
Apr 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders:    Cylinder Storage Area, West Loading Dock: On March 14, 2012, and at times prior thereto,  four acetlyene cylinders where stored within five feet of approximately a dozen oxygen cylinders.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 2 instances 2200 exposed
Issued
Apr 24, 2012
Abate by
May 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    HVAC/Equipment Shop: On March 13, 2012, and at times prior thereto, two power taps did not meet the specifications for use in a commerical/industrial location.
Recent events (1)
  • · Z (S) $0

1910.303 E01 I

Serious Gravity 5 2 instances 2200 exposed
Issued
Apr 24, 2012
Abate by
May 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(i): The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product was not identified on electrical equipment:    On March 13, 2012, and at times prior thereto, in the following locations, homemade electrical outlets were not descriptively marked;  A. East loading dock by exit door: A fire alarm was energized by a homemade junction box.  B. HVAC/Equipment Shop: A metal outlet box was covered with plastic outlet cover and energized a hot water dispenser.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Repeat Gravity 5 5 instances 2200 exposed
Issued
Apr 24, 2012
Abate by
May 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used for purposes prohibited by subparagraphs (a) through (f) of this paragraph:    On March 13, 2012 and at times prior thereto, in the following locations, extension cords were being used in lieu of permanent wiring;    A. East loading dock: To energize refrigerators during trouble shooting.  B. HVAC/Equipment Shop, Lunch Area: To energize a fry-o-lator.  C. Electrical Room B231: To energize the Wireguard System for the Community Living Center.  D. Chemistry Lab, Rm 1242: One extension cord energized the OceanAire Portable AC Unit and another energized a UPS battery back up system.      The U.S. Department of Veterans Affairs was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.305(g)(1)(iv)(A) which was contained in OSHA Inspection Number 315053777, Citation Number 01, Item Number 006, issued on 03/07/2012, with respect to a workplace located at 5901 E 7th Street, Long Beach, CA 90822, which became final order on 03/29/2011.
Recent events (1)
  • · Z (R) $0

View U.S. Department of Veteran Affairs's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332811561.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.