COLUMBIA, MO —
OSHA Inspection: COIL CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COIL CONSTRUCTION, INC. in 20 BOURN AVENUE, COLUMBIA, MO 65203 (NAICS 236116). OSHA activity number 332811603.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COIL CONSTRUCTION, INC.
- Site address
- 20 BOURN AVENUE
- City
- COLUMBIA
- State
- MO
- ZIP
- 65203
- Mailing
- 203 EAST BROADWAY, COLUMBIA, MO 65203
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Apr 6, 2012
- Penalty
- Initial $2,040 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is not fully decked. On or about 02/28/2012 at worksite 20 Bourn Avenue in Columbia, Missouri- Employees were performing masonry work at a height greater than 12 feet on a working level that was not fully planked. Abatement certification for this violation is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $2040
1926.451 E01
- Issued
- Apr 6, 2012
- Penalty
- Initial $1,734 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. On or about 02/28/2012 at worksite 20 Bourn Avenue in Columbia, Missouri- Employees were accessing scaffold platforms more than 2 feet (0.6 m) above and below points of access. Abatement certification for this violation is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $1734
1926.451 G01
- Issued
- Apr 6, 2012
- Penalty
- Initial $3,780 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about 02/28/2012 at worksite 20 Bourn Avenue in Columbia, Missouri- Employees were performing masonry work on a scaffold at a height greater than 12 feet and were not protected from fall by means of guardrails or any other personal fall arrest system. Abatement certification for this violation is not required.
Recent events (2)
- — I (S) $0
- — Z (S) $3780
More inspections at Coil Construction, INC.
View Coil Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332811603.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.