Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J GONZALEZ ROOFING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J GONZALEZ ROOFING COMPANY in 3059 N. SOUTHPORT AVE., CHICAGO, IL 60657 (NAICS 238160). OSHA activity number 332812346.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J Gonzalez Roofing Company — free Get an email when a new federal OSHA severe-injury report for J Gonzalez Roofing Company is published. One employer, no account, unsubscribe in one click.
Site address
3059 N. SOUTHPORT AVE.
City
CHICAGO
State
IL
ZIP
60657
Mailing
3318 N. KILDARE, CHICAGO, IL 60641
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 2 exposed
Issued
Apr 11, 2012
Abate by
Apr 12, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a)  Employees were exposed to fall hazards of approximately 3 stories while dumping material into a debris chute.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.501 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 11, 2012
Abate by
Apr 12, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    a)  Employees were exposed to fall hazards while working around unprotected skylights.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1926.501 B10

Serious Gravity 10 2 exposed
Issued
Apr 11, 2012
Abate by
Apr 12, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:    a)  Employees engaged in roofing activities were exposed to falls of approximately 3 stories.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.