ROCHESTER, NY —
OSHA Inspection: SUMMIT HOSPITALITY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SUMMIT HOSPITALITY, INC. in 70 STATE STREET, ROCHESTER, NY 14614 (NAICS 721110). OSHA activity number 332812775.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUMMIT HOSPITALITY, INC.
- Site address
- 70 STATE STREET
- City
- ROCHESTER
- State
- NY
- ZIP
- 14614
- Mailing
- 70 STATE STREET, ROCHESTER, NY 14614
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 65
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.305 B02 I
- Issued
- May 4, 2012
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy Rochester Plaza Hotel, 6th floor utility/service area - On or about 03/08/2012, an outlet box in a completed installation did not have a cover or faceplate.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.305 G01 IV D
- Issued
- May 4, 2012
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: Rochester Plaza Hotel, 6th floor service/utility area - On or about 03/08/2012, a flexible cord, used to power a wireless router, was attached to building surfaces.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1926.1101 K06
- Issued
- May 4, 2012
- Abate by
- Jun 3, 2012
- Penalty
- Initial $3,500 · Current $2,625 Reduced
General-duty citation text
29 CFR 1926.1101(k)(6): At the entrance of the mechanical rooms/areas in which employees could reasonably be expected to enter and which contained ACM and/or PACM, the building owner did not post signs identifying the material present, its location, and appropriate work practice which, if followed will ensure that asbestos containing material and/or presumed asbestos containing material will not be disturbed: Rochester Plaza Hotel - 3rd floor mechanical room, basement mechanical room - there were no asbestos warning signs posted at the entrance to the mechanical rooms in which employees were expected to enter which contain ACM and/or PACM. Rochester Plaza Hotel - 6th floor utility room, adjacent to service elevator - there were no asbestos warning signs posted at the entrance to the mechanical rooms in which employees were expected to enter which contain ACM and/or PACM.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1926.1101 K09 I
- Issued
- May 4, 2012
- Abate by
- Jun 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(9)(i): The employer did not institute, at no cost to employees, a training program for each employee who was likely to be exposed in excess of the permissible exposure limit (PEL) and for each employee who performed Class I through IV asbestos operations: Rochester Plaza Hotel - 3rd floor mechanical room, basement mechanical room - the employer did not insitute a and ensure participation in an asbestos training program for maintenance employees who perform Class IV asbestos operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 L04
- Issued
- May 4, 2012
- Abate by
- Jun 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(l)(4): Waste and debris and accompanying dust in an area containing accessible thermal system insulation or surfacing ACM/PACM or visibly deteriorated ACM was not promptly cleaned up: Rochester Plaza Hotel, 3rd floor mechanical room and 6th floor service/utility area - On or about 03/08/2012, debris and accompanying dust in an area containing accessible thermal system insulation ACM/PACM was not promptly cleaned up.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- May 4, 2012
- Abate by
- Jun 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderlyand in a sanitary condition. a) Rochester Plaza Hotel - guest rooms 435, 461, and 661 - On or about 03/14/2012, the employer did not maintain the workplace in a clean and sanitary condition as surface mold had developed on the walls of the rooms. b) Rochester Plaza Hotel - parking garage - On or about 03/08/2012, the employer did not maintain the workplace in a clean and sanitary condition as lint and airborne particulate had accumulated on the air intake filter of the laundry dryers.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Summit Hospitality, INC.