Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: R & G GRANITE WORKS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of R & G GRANITE WORKS in 7000 E. 58TH AVE. UNIT A, COMMERCE CITY, CO 80022 (NAICS 327991). OSHA activity number 332815968.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & G Granite Works for free Get an email when a new federal OSHA severe-injury report for R & G Granite Works is published. One employer, no account, unsubscribe in one click.
Establishment
R & G GRANITE WORKS
Site address
7000 E. 58TH AVE. UNIT A
City
COMMERCE CITY
State
CO
ZIP
80022
Mailing
835 S. VANCE ST APT C-211, LAKEWOOD, CO 80226
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
7
Ownership type
Private (A)

11 citations on file for this inspection.

1910.212 A05

Serious Gravity 1 1 instance 5 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.212(a)(5):  Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one-half inch:    R & G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the fan blades of a fan located on the floor by the garage door had openings larger than 6 inches on the side of the work shop area. This condition exposed the employees to an amputation hazard.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800

1910.215 B05

Serious Gravity 1 1 instance 5 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.215(b)(5):  The angular exposure of grinding wheel periphery and sides for safety guards used on surface grinding machine(s) employing the wheel periphery exceeded 150 degrees:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the employer did not ensure that guards were installed on the Makita 4 1/2" angle grinder, serial number 147614A, and Makita 4 1/2" angle grinder, serial number 146924A, used in the granite shop. This condition exposed employees to the hazard of being struck by shrapnel in the event of a grinding wheel failure.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800

1910.303 B02

Serious Gravity 5 2 instances 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the 13-amp Skilsaw HD77 circular hand saw was not used in accordance with the operating instructions, in that employees pour water from a container onto the saw blade of the Skilsaw while cutting on granite. This saw is not rated to be used with water. This condition exposed the employees to the hazard of electrical shock.    (b)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the main circuit breaker panel board located on the north wall in the shop was not installed in accordance with its listing. The circuit break panel is incorrectly recessed into its enclosure, thus causing a one to two-inch opening surrounding the circuit breakers. This condition exposed the employees to the hazard of electrical shock.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1910.305 E01

Serious Gravity 1 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.305(e)(1):  Cabinets, cutout boxes, fittings, boxes, and panel board enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the main circuit breaker panel board located on the west wall was not installed to prevent moisture or water from entering and accumulating within the enclosure. Employees use water on saws while cutting granite slabs, thus causing standing water to cover the floor of the shop, in addition to water spraying the work area. This condition exposed employees to the hazard of electrical shock and burns.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800

1910.305 J02 IV

Serious Gravity 1 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv):  Receptacles installed in wet or damp locations were not suitable for the location:    (a)  On or before March 17, 2009, the 120-volt electrical receptacles installed throughout the granite shop are not rated for wet or damp locations. Employees use water on saws while cutting granite slabs, thus causing standing water to cover the floor of the shop, in addition to water spray in the work area. This condition exposed employees to the hazard of electrical shock and burns.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.334(a)(2)(i):  Portable cord and plug connected electrical equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the outer insulation jacket on the flexible power extension cord used with the Skilsaw HD77 circular hand saw was damaged. This condition exposed the employees to the hazard of electrical shock.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1800

1910.304 G05

Serious Gravity 1 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures was not permanent and continuous:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the employer did not ensure that the path to ground for the Blue Ripper stone saw was continuous. The grounding prong in the 3-prong grounding AC plug was damaged and loose. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):  Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the electrical power extension cord used on the south wall was not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. The inner conductor wires were exposed due to damaged cord sheathing. This condition exposed the employee to electrical shock.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Other-than-serious 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 psi:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the employer did not ensure the compressed air nozzle used for cleaning off equipment in the facility was reduced to less than 30 psi. The compressed air line was pressurized at approximately 125 psi. This condition exposed employees using the air hose to the hazard of an embolism in the blood stream.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 F02

Other-than-serious 1 instance 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):  Each service, feeder and branch circuit, at its disconnecting  means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the employer did not ensure each circuit breaker was identified in the main circuit breaker panel board located on the north wall in the shop. Each circuit break was not marked to indicate its purpose. This condition exposed the employees to electrical hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B02 I

Other-than-serious 2 instances 7 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):  Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the electrical outlet junction box located on the south wall did not have the correct cover installed, thus potentially exposing employees to energized parts. This condition exposed the employees to the hazard of electrical shock.    (b)  R and G Granite Works at 7000 E. 58th Ave., Unit A, Commerce City, CO 80022:  On and before February 9, 2012, the main circuit breaker panel board located on the north wall in the shop did not have the cover installed. This condition exposed the employees to the hazard of electrical shock.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View R & G Granite Works's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332815968.