OSHA Inspection: THE MENNEL MILLING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE MENNEL MILLING COMPANY in 2600 N. DIXIE HIGHWAY, TROY, OH 45373 (NAICS 493130). OSHA activity number 332818715.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Mennel Milling Company for free Get an email when a new federal OSHA severe-injury report for The Mennel Milling Company is published. One employer, no account, unsubscribe in one click.
Site address
2600 N. DIXIE HIGHWAY
City
TROY
State
OH
ZIP
45373
Mailing
128 W. CROCKER ST., FOSTORIA, OH 44830
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
9
Ownership type
Private (A)

10 citations on file for this inspection.

1910.23 A03

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 9, 2012
Abate by
May 21, 2012
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.23(a)(3):   Every hatchway and chute floor opening was not guarded by one of the following: (i) Hinged floor opening cover, (ii) A removable railing with toe board:    (a)  On the third floor of the Mill building, there was chute floor opening measuring 20" by 30" that was not guarded.  (b)  On the #4 Bin roof deck, there were two triangular shaped floor openings that were not guarded.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $4000

1910.23 A08 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8)(ii):   Every floor hole into which persons could accidentally walk was not guarded by a floor hole cover of standard strength and construction:    (a)  In the Mill building on the third floor stairway landing, there was a 9 7/8" by 9 7/8" square floor hole that was not covered.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.23 B01

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.23(b)(1):   Every wall opening from which there is a drop of more than 4 feet shall be guarded:    (a) On the #4 Bin Deck, there was an inadequately guarded wall opening on the west side in that the top rail was too high (43 1/2 to 44 inches high) and no mid-rail.     (b) In the Mill building, on the 4th floor east side, there was a wall opening that was missing the top rail and the mid rail was too high (25 1/2 inches off the floor).    (c)  In the Mill building on the second floor, there were wall openings on each side of the grain chutes that were not guarded with standard guard railing.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $5000

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1):   Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    (a)  On or about March 2, 2012, the hinged platform used while loading trucks had no guardrailing or equivalent protection on all open sides.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.272 G04

Other-than-serious 6 instances 2 exposed
Issued
Apr 9, 2012
Abate by
May 21, 2012
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.272(g)(4):   The employer did not provide equipment for rescue operations, which was specifically suited for the bin, silo, or tank being entered:    (a) On or about February 24, 2012, Bins #39 and 47 were entered to clean out the bins and emergency rescue equipment was not provided.    (b) On or about February 3, 2012, Bins #13, 14, 16, and 27 were entered to clean out the bins and emergency rescue equipment was not provided.
Recent events (2)
  • · I (O) $0
  • · Z (S) $5000

1910.304 A02

Deleted Serious Gravity 1 3 instances 3 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.304(a)(2):   Grounded conductors were attached to terminals or leads so as to reverse designated polarity:    (a) In the Maintenance shop, the three (3) 110v outlets that were tested had reversed polarity.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3000

1910.304 G05

Serious Gravity 1 3 instances 2 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.304(g)(5):   The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective:    (a)  In the Maintenance shop, the 110v outlet that the bench grinder and the light with a metal shade did not have low impedance paths to ground (2.5 ohms resistance).    (b)  In the Maintenance shop, the two (2) other 110v outlets that were tested also had high impedance paths to ground (4.0 ohms on wall outlet and 2.5 ohms on the outlet mounted on I-beam column).
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.305 G01 IV C

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 9, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.305(g)(1)(iv)(C):   Flexible cords and cables were run through doorways, windows, or similar openings:    (a) On the #1 Bin Deck, Head House, there was a flexible cord run through a window opening and a hole cut in the screen to power a light at the turn head.    (b) On the #3 Bin Deck, there was a flexible cord run through a doorway with a metal door to power the temperature monitor sending unit.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 9, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.305(g)(2)(iii):   Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) In the Maintenance building, there was a flexible cord powering the old pedestal fan that did not have strain relief at the fan motor connection and was pulled loose, as well as having damage to the outer insulation in the length of the cord.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.24 E

Other-than-serious 1 instance 2 exposed
Issued
Apr 9, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.24(e):   Fixed stairs were not installed at angles to the horizontal of between 30deg. and 50 deg. Any uniform combination of rise/tread dimensions may be used that will result in a stairway at an angle to the horizontal within the permissible range. Table D-1 gives rise/tread dimensions which will produce a stairway within the permissible range, stating the angle to the horizontal produced by each combination:  (However, the rise/tread combinations are not limited to those given in Table D-1).    (a)  In the Mill building, there was a metal stairway between the second and third floors that was too steep (approx. 60 degrees).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0