Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: MAGICSCARF.COM, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAGICSCARF.COM, INC. in 19 POND ROAD, GLOUCESTER,, GLOUCESTER, MA 01930 (NAICS 448190). OSHA activity number 332819176.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Magicscarf.Com, INC. for free Get an email when a new federal OSHA severe-injury report for Magicscarf.Com, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19 POND ROAD, GLOUCESTER,
City
GLOUCESTER
State
MA
ZIP
01930
Mailing
19 POND ROAD, GLOUCESTER,, GLOUCESTER, MA 01930
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
448190
Employees
24
Ownership type
Private (A)

6 citations on file for this inspection.

1910.176 B

Serious Gravity 5 5 instances 6 exposed
Issued
Jul 2, 2012
Abate by
Aug 14, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.176(b):     Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    Location: Warehouse    On or about 3/16/12, employees working in the warehouse were exposed to overhead struck by hazards in the following areas;    1. Rack W3SCARF-3  2 boxes of scarfs weighing approximately 80-pounds stored on top of another box on a shelf approximately 9-feet in height was leaning inwards towards the aisle.  2. Rack W3A401-3  10 boxes of reversible vests stored on top of other boxes approximately 12-feet in height was leaning inwards and towards the aisle.  3. Rack W2A207-2  4 boxes of petal shirts stored on top of other boxes approximately 10-feet in height was leaning inwards and towards the aisle.  4. Rack W2A5-2  23 boxes of miscellaneous clothing stored on top of a shelf that was bent towards the middle of the shelf and stored approximately 13-feet in height was leaning inwards towards the aisle.  5. Rack W1A1-4  the vertical upright of the rack stacked with boxes of merchandise was bent and twisted upright.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.303 B07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2012
Abate by
Aug 14, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.303(b)(7)(i):     Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:    Location: Warehouse    On or about 3/16/12, the employer did not install the faceplate cover of the electrical outlet and light switch box that supplied power to two outlets and a light switch.  The 110-volt internal wires exposed employees who turn on and off the lights to the warehouse and that use the two extension cords to electrical shock hazards.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.305 G01 IV B

Serious Gravity 5 1 instance 24 exposed
Issued
Jul 2, 2012
Abate by
Aug 14, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.305(g)(1)(iv)(B):     Flexible cords and cables were run through holes in walls, ceilings, or floors;    Location:  Warehouse dock area    On or about 3/16/12, employees were exposed to fire hazards and electric shock hazards from an extension cord running through a wall from the office area to the dock area.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1910.334 A02 I

Serious Gravity 5 1 instance 24 exposed
Issued
Jul 2, 2012
Abate by
Aug 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    Location:  Dock Area    On or about 3/16/12, an extension cord running along the concrete floor was damaged and frayed exposing the internal wires of the cord.  The employer did not do visual inspections of extension cords.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 C01

Other-than-serious 1 instance 24 exposed
Issued
Jul 2, 2012
Abate by
Aug 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):     Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    Location:  Office    On or about 3/16/12, the employer did not mount the fire extinguisher in the office area to provide readily accessibility.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E03

Other-than-serious 1 instance 24 exposed
Issued
Jul 2, 2012
Abate by
Aug 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):     Portable fire extinguishers were not subjected to an annual maintenance check:    Location:  Back wall of Warehouse    On or about 3/16/12, the employer did not assure that the portable fire extinguisher was subjected to an annual maintenance check.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332819176.