FAIRFIELD, NJ ·
OSHA Inspection: SUN DIAL & PANEL CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SUN DIAL & PANEL CORPORATION in 2 DANIEL ROAD, FAIRFIELD, NJ 07004 (NAICS 336413). OSHA activity number 332820463.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUN DIAL & PANEL CORPORATION
- Site address
- 2 DANIEL ROAD
- City
- FAIRFIELD
- State
- NJ
- ZIP
- 07004
- Mailing
- 2 DANIEL ROAD, FAIRFIELD, NJ 07004
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336413
- Employees
- 15
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1910.106 E02 II B 1
- Issued
- Aug 31, 2012
- Abate by
- Sep 24, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b)(1): The quantity of liquid that may be located outside of an inside storage room or flammables storage cabinet in a building or in any one fire area of a building exceeded 25 gallons of Category 1 flammable liquids in containers. Workplace, 2 Daniel Road, Fairfield, NJ a) Approximately 60 gallons of Category 1 flammable liquids that included reducer and paint containers were not stored in a flammable storage cabinet. Violation occurred on or about 3-6-12.
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.107 B01
- Issued
- Aug 31, 2012
- Abate by
- Sep 15, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
0440
General-duty citation text
29 CFR 1910.107(b)(1): Spray booths were not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry, or aluminum or other substantial noncombustible material. Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform flammable paint spray application onto products they manufacture. The employees apply the Sherwin Williams Polane T paint in a Spray Tech spray booth. The spray booth walls and floor were covered in cardboard, a combustible material. Violation occurred on or about 3-6-12.
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.107 B05 I
- Issued
- Aug 31, 2012
- Abate by
- Sep 24, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
0440
General-duty citation text
29 CFR 1910.107(b)(5)(i): The spraying operations except electrostatic spraying operations were not so designed, installed and maintained so that the average air velocity over the open face of the booth (or booth cross section during spraying operations) was at least 100 linear feet per minute. Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained. Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform flammable paint spray application onto products they manufacture. The employees apply the Sherwin Williams Polane T paint in a Spray Tech spray booth. The spray booth was operated with an average air velocity over the open face of the booth of 48 fpm. b) The employer directed employees to perform flammable paint spray application in the Spray Tech spray booth onto products they manufacture, without installing a visible gauge or audible alarm to insure that the required air velocity is maintained, prior to the spray application. Violation occurred on or about 3-6-12
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.107 B09
- Issued
- Aug 31, 2012
- Abate by
- Sep 15, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
0440
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform Sherwin Williams Polane T flammable paint spray application with products they manufacture. The employees apply this flammable paint in a Spray Tech spray booth. Abutting the booth face exterior is a small wooden stand, and approximately 1 foot from the booth face is a wooden table approximately 3 x 1.5 x 10 feet in size. Violation occurred on or about 3-6-12
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.107 C06
- Issued
- Aug 31, 2012
- Abate by
- Sep 15, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
0440
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: Workplace, 2 Daniel Road, Fairfield, NJ The employer directed employees to perform Sherwin Williams Polane T flammable paint spray application onto products they manufacture. The employees apply this flammable paint in a Spray Tech spray booth. The following devices were located within 20 feet of the spraying area: a) Two 120 Volt electrical outlets, one approximately 3 feet and the 2nd approximately 8 feet from the spray booth. b) Approximately 8 standard 120 Volt light fixtures in the ceiling, approximately 6 to 11 feet from the spray booth. Violation occurred on or about 3-6-12
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.107 D03
- Issued
- Aug 31, 2012
- Abate by
- Sep 15, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
0440
General-duty citation text
29 CFR 1910.107(d)(3): Each spray booth did not have an independent exhaust duct system discharging to the exterior of the building. a) The spray booth does not have an independent exhaust system that ducts to the exterior of the building. Violation occurred on or about 3-6-12
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.134 C
- Issued
- Aug 31, 2012
- Abate by
- Sep 24, 2012
- Penalty
- Initial $4,000 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform Sherwin Williams Polane T flammable paint spray application onto products they manufacture. The employer provided and required the use of two negative pressure elastomeric 1/2 mask respirators to employees who perform the flammable paint spraying. The employer did not develop and implement a written respiratory protection program with required worksite specific procedures. Violation occurred on or about 3-6-12.
Recent events (2)
- · I (S) $1440
- · Z (S) $4000
1910.134 E01
- Issued
- Aug 31, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform Sherwin Williams Polane T flammable paint spray application onto products they manufacture. The employer provided and required the use of two negative pressure elastomeric 1/2 mask respirators to employees who perform the flammable paint spraying. The employer did not provide the employees with a medical evaluation to determine if they can safely use a respirator. Violation occurred on or about 3-6-12.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 K
- Issued
- Aug 31, 2012
- Abate by
- Sep 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform Sherwin Williams Polane T flammable paint spray application onto products they manufacture. The employer provided and required the use of two negative pressure elastomeric 1/2 mask respirators to employees who perform the flammable paint spraying. The employer did not train employees in the correct use and maintenance of the respirators they use. Violation occurred on or about 3-6-12.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 F02
- Issued
- Aug 31, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: Workplace, 2 Daniel Road, Fairfield, NJ a) The employer directed employees to perform Sherwin Williams Polane T flammable paint spray application onto products they manufacture. The employer provided and required the use of two negative pressure elastomeric 1/2 mask respirators to employees who perform the flammable paint spraying. The employer did not provide employees with a respirator fit test prior to the paint spraying. Violation occurred on or about 3-6-12.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 336413)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332820463.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.