Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLEXICORE OF TEXAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLEXICORE OF TEXAS in 8634 MCHARD ROAD, HOUSTON, TX 77053 (NAICS 327390). OSHA activity number 332821222.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flexicore of Texas — free Get an email when a new federal OSHA severe-injury report for Flexicore of Texas is published. One employer, no account, unsubscribe in one click.
Establishment
FLEXICORE OF TEXAS
Site address
8634 MCHARD ROAD
City
HOUSTON
State
TX
ZIP
77053
Mailing
8634 MCHARD RD., HOUSTON, TX 77053
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
217
Ownership type
A

13 citations on file for this inspection.

1910.180 D03

Other-than-serious 2 instances 5 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $6,300 · Current $4,550 Reduced
29 CFR 1910.180(d)(3): "Frequent inspection." Items such as the following shall be inspected for defects at intervals as defined in paragraph (d)(2)(i) of this section or as specifically indicated including observation during operation for any defects which might appear between regular inspections. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:    On or about March 31, 2012, two Galion 150 series hydraulic cranes at the work site did not have a current annual inspection.
Recent events (2)
  • — I (O) $4550
  • — Z (S) $6300

1910.23 A02

Serious Gravity 5 4 instances 2 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $4,500 · Current $2,300 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:    On March 21, 2012, at 8634 McHard Rd, Houston, TX, employees are exposed to fall hazards greater than 4 feet above the lower level when on the platforms in the batch plant.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $4500

1910.178 L01 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l)    On March 21, 2012, at 8634 McHard Road, Houston, TX, employees are exposed to struck by hazards when using untrained forklift operators to haul containers of concrete.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.178 N04

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.178(n)(4): Where the load being carried obstructed forward view, drivers were not required to travel with the load trailing    On March 21, 2012, at 8634 McHard Road, Houston, TX, employees are exposed to struck by hazards when the forklift operators haul the containers of concrete above the line of view of the operator while travelling forward.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.178 N07 III

Deleted Serious Gravity 5 3 instances 1 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(n)(7)(iii): On all grades the load and load engaging means was not tilted back and raised only as far as necessary to clear the road surface.      On March 21, 2012, at 8634 McHard Road, Houston, TX, employees are exposed to struck by hazards when the forklift operators haul the containers of concrete above the line of view of the operator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J02

Other-than-serious 4 instances 4 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.179(j)(2):     The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard:    (a) on March 21, 2012, at 8634 McHard Road, Houston, TX, a rubber tired gantry crane, Mijack (MJ-1), Model 650A1, Serial No. 3169, is used to lift concrete beams had not been inspected since November 12, 2010.    (b) on March 21, 2012, at 8634 McHard Road, Houston, TX, a rubber tired gantry crane, Mijack (MJ-2), Model 650C, Serial No. 6209505, is used to lift concrete beams had not been inspected since November 12, 2010.    (c) on March 21, 2012, at 8634 McHard Road, Houston, TX, a rubber tired gantry crane, Mijack (MJ-3), Model MJ50, Serial No. 1649, is used to lift concrete beams had not been inspected since November 12, 2010.    (d) on March 21, 2012, at 8634 McHard Road, Houston, TX, in the carpenter shop, a 10 ton overhead gantry, Halbert Hoist Incorporated, serial # 1624 has not been inspected in the last 12 months.
Recent events (2)
  • — I (O) $6300
  • — Z (S) $6300

1910.179 J03

Other-than-serious 1 instance 3 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:    (a) on March 21, 2012, at 8634 McHard Road, Houston, TX, a rubber tired gantry crane, Mijack (MJ-1), Model 650A1, Serial No. 3169, is used to lift concrete beams had not been inspected since November 12, 2010.    (b) on March 21, 2012, at 8634 McHard Road, Houston, TX, a rubber tired gantry crane, Mijack (MJ-2), Model 650C, Serial No. 6209505, is used to lift concrete beams had not been inspected since November 12, 2010.    (c) on March 21, 2012, at 8634 McHard Road, Houston, TX, a rubber tired gantry crane, Mijack (MJ-3), Model MJ50, Serial No. 1649, is used to lift concrete beams had not been inspected since November 12, 2010.    (d) on March 21, 2012, at 8634 McHard Road, Houston, TX, in the carpenter shop, a 10 ton overhead gantry, Halbert Hoist Incorporated, serial # 1624 has not been inspected in the last 12 months.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6300

1910.253 B02 IV

Other-than-serious 1 instance 2 exposed
Issued
Sep 6, 2012
Abate by
Oct 6, 2012
Penalty
Initial $4,500 · Current $2,300 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    On March 21, 2012, and times prior to, in the Batch Plant, employees were exposed to fire and explosion hazards when storing oxygen and acetylene cylinders with the gauges on the cylinders.
Recent events (2)
  • — I (O) $2300
  • — Z (S) $4500

1910.304 B03 II A

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Sep 6, 2012
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel.    On March 21, 2012, in the fire proofing area break room, employees were exposed to electric shock when running a flexible cord from a 120 volt outlet, through a closed door, to energize a radio and fan.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.305 A02 X

Other-than-serious 1 instance 10 exposed
Issued
Sep 6, 2012
Penalty
Initial $6,300 · Current $6,000 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.    On March 21, 2012, in the fire proofing area break room, employees were exposed to electric shock when running a flexible cord from a 120 volt outlet, through a closed door, to energize a radio and fan.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $6300

1910.334 A02 I

Other-than-serious 1 instance 10 exposed
Issued
Sep 6, 2012
Abate by
Nov 6, 2012
Penalty
Initial $6,300 · Current $6,000 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    On March 21, 2012, in the fire proofing area break room, employees were exposed to electric shock when using a damaged flexible cord from a 120 volt outlet, through a closed door, to energize a radio and fan.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $6300

1910.1200 H01

Other-than-serious 1 instance 200 exposed
Issued
Sep 6, 2012
Abate by
Nov 6, 2012
Penalty
Initial $2,700 · Current $2,700
29 CFR 1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets:    on March 21, 2012, at 8634 McHard Road, Houston, TX, employees are exposed to inhalation and skin contact hazards when working with chemicals such as but not limited to Portland cement (crystalline silica), spec strip (naphthenic distillates), acetylene, oxygen, gasoline, and diesel.
Recent events (2)
  • — I (O) $2700
  • — Z (S) $2700

1910.26 C02 VII

Other-than-serious 1 instance 1 exposed
Issued
Sep 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.26(c)(2)(vii):  Ladders having defects were not marked and taken out of service until repaired.    On March 21, 2012, in the Batch Unit, a 6 foot, metal, "A" framed ladder was used daily by maintenance.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Flexicore of Texas's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332821222.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.