Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LEON'S ROOFING & SIDING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LEON'S ROOFING & SIDING in 4660 STONEWOOD DR., MIDDLETON, WI 53562 (NAICS 236118). OSHA activity number 332822006.

Watch Leon'S Roofing & Siding — free Get an email when a new federal OSHA severe-injury report for Leon'S Roofing & Siding is published. One employer, no account, unsubscribe in one click.
Site address
4660 STONEWOOD DR.
City
MIDDLETON
State
WI
ZIP
53562
Mailing
7130 LEE RD., LODI, WI 53555
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2500.00 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.                            Employees were not provided with safety glasses while using a pnuematic nail gun to install shingles on a roof.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3600

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8400.00 · Current $5800.00 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.        Employees installings shingles on a roof were not protected from falling to lower levels.        Leon's Roofing & Siding was previoulsy cited for a violation of this occupational safety and health standard or its equivalent standard, 1926.501(b)(13), which was contained in OSHA inspection number 313136392, citation number 01, item number 01 and was affirmed as a final order on 12/16/2010, with respect to a workplace located at 7397 Mineral Point Rd. Verona, WI 53593.
Recent events (2)
  • — I (R) $5800
  • — Z (R) $8400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332822006.