Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: PROFICIENT PLASTICS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PROFICIENT PLASTICS, INC in 7777 ST. CLAIR AVE., MENTOR, OH 44060 (NAICS 325991). OSHA activity number 332822014.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Proficient Plastics, INC for free Get an email when a new federal OSHA severe-injury report for Proficient Plastics, INC is published. One employer, no account, unsubscribe in one click.
Site address
7777 ST. CLAIR AVE.
City
MENTOR
State
OH
ZIP
44060
Mailing
P.O. BOX 5053, MENTOR, OH 44061
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325991
Employees
20
Ownership type
A

7 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 19, 2012
Abate by
May 3, 2012
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1910.132(a):     Protective equipment, including personal protective equipment for the eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used and maintained in a sanitary and reliable condition whereever it was necessary by reason of hazards of processes or enviornmental, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    Fall protection was not provided for employees who have to climb on top of the mold machines which are approximately 6 to 15 feet high to check sensors.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2400

1910.132 D02

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 19, 2012
Abate by
May 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2):     The employer did not verify that the required workplace hazard assessment had been performed through written certification that identified the workplace evaluated; the person certifying that the evaluation had been performed; the date(s) of the hazard assessment; and, identified the document as a certification of the hazard assessment:    The required workplace assessment was not written and certified as being performed.    Employees who are required to check sensors on mold machines which are approximately 6 to 15 feet high, were not provided fall protection.    The employer shall:    (a)  Select, and have each affected employee use the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment;    (b)  Communicate selection decision to each affected employee; and,    (c)  Select PPE that properly fits each affected employee
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.132 F01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 19, 2012
Abate by
May 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1):     The employer did not provide training to each employee who is required by this section to use personal protective equipment:    The employer shall provide training to each employee who is required to use PPE, such as, but not limited to, safety glasses, heat resistant gloves, fall protection, etc.  Each employee shall be trained to know at least the following:    (a)  When PPE is necessary    (b)  What PPE is necessary    (c)  How to properly don, doff, adjust and wear PPE    (d)  The limitations of the PPE, and    (e)  The proper care, maintenance, useful life and disposal of the PPE
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2012
Abate by
May 19, 2012
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    The company did not establish a program to protect employees involved with servicing and maintenance of machines and equipment from the unexpected energizing, start up or release of stored energy.  Energy sources, included, but are not limited to, electrical, pneumatic, hydraulic, etc.  The company maintains and servides equipment such as, but not limited to, plastic injection molding machines, etc.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2400

1910.219 E01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 19, 2012
Abate by
Apr 26, 2012
Penalty
Initial $1,800 · Current $1,260 Reduced
29 CFR 1910.219(e)(1)(i):     Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:    Grit station:  The belt for the motor was not fully enclosed.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $1800

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 19, 2012
Abate by
Apr 26, 2012
Penalty
Initial $1,800 · Current $1,260 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    A power strip that was not rated for industrial use was being used to power an air cylinder, fan, etc.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $1800

1910.305 G01 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 19, 2012
Abate by
May 3, 2012
Penalty
Initial $1,800 · Current $1,260 Reduced
29 CFR 1910.305(g)(1)(iii)(A):     Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:    Extension cords were used in lieu of fixed wiring for the Grit station.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $1800

View Proficient Plastics, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332822014.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.