Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: AZTEC GENERAL CONTRACTORS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AZTEC GENERAL CONTRACTORS, LLC in 2201 LAKE AVE., PUEBLO, CO 81004 (NAICS 236220). OSHA activity number 332824101.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aztec General Contractors, LLC for free Get an email when a new federal OSHA severe-injury report for Aztec General Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2201 LAKE AVE.
City
PUEBLO
State
CO
ZIP
81004
Mailing
4004 MARK DABLIN BLVD., COLORADO SPRINGS, CO 80907
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
4
Ownership type
Private (A)

6 citations on file for this inspection.

1926.451 B01 I

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
May 21, 2012
Abate by
May 24, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.451(b)(1)(i):  Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.    (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they were working from a five-level scaffold and a six-level scaffold that were not fully planked around a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $4200

1926.451 F04

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
May 21, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(4):  Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired.  (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they were working from a five-level scaffold and a six-level scaffold with planking that was cracked, split, splintering, and otherwise damaged, at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 E01

Other-than-serious 1 instance 5 exposed
Issued
May 21, 2012
Abate by
May 24, 2012
Penalty
Initial $4,200 · Current $3,360 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they accessed the top three levels of the five-level scaffold and top four levels of the six-level scaffold by climbing the crossbraces.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $3360
  • · Z (S) $4200

1926.451 E05 I

Other-than-serious 1 instance 5 exposed
Issued
May 21, 2012
Abate by
May 24, 2012
Penalty
Initial $3,000 · Current $2,400 Reduced
29 CFR 1926.451(e)(5)(i):  Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection:  (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they accessed the roof from the scaffold using ramps that were not guarded at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $2400
  • · Z (S) $3000

1926.451 G04 I

Other-than-serious 1 instance 5 exposed
Issued
May 21, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i):  Guardrail systems were not installed along all open sides and ends of platforms.  (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards while working from a five-level scaffold and a six-level scaffold with incomplete guardrails at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1926.451 H02 II

Other-than-serious 1 instance 5 exposed
Issued
May 21, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(h)(2)(ii):   A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:  (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from objects falling from overhead in that toeboards were not erected along all scaffold platforms on which employees were working at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332824101.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.