PUEBLO, CO ·
OSHA Inspection: AZTEC GENERAL CONTRACTORS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AZTEC GENERAL CONTRACTORS, LLC in 2201 LAKE AVE., PUEBLO, CO 81004 (NAICS 236220). OSHA activity number 332824101.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AZTEC GENERAL CONTRACTORS, LLC
- Site address
- 2201 LAKE AVE.
- City
- PUEBLO
- State
- CO
- ZIP
- 81004
- Mailing
- 4004 MARK DABLIN BLVD., COLORADO SPRINGS, CO 80907
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.451 B01 I
- Issued
- May 21, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they were working from a five-level scaffold and a six-level scaffold that were not fully planked around a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (S) $0
- · Z (S) $4200
1926.451 F04
- Issued
- May 21, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they were working from a five-level scaffold and a six-level scaffold with planking that was cracked, split, splintering, and otherwise damaged, at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 E01
- Issued
- May 21, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $4,200 · Current $3,360 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they accessed the top three levels of the five-level scaffold and top four levels of the six-level scaffold by climbing the crossbraces. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $3360
- · Z (S) $4200
1926.451 E05 I
- Issued
- May 21, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $3,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards when they accessed the roof from the scaffold using ramps that were not guarded at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $2400
- · Z (S) $3000
1926.451 G04 I
- Issued
- May 21, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from fall hazards while working from a five-level scaffold and a six-level scaffold with incomplete guardrails at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $0
- · Z (S) $0
1926.451 H02 II
- Issued
- May 21, 2012
- Abate by
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: (a) On or about March 22, 2012, and at times prior, Aztec General Contractors, LLC, as controlling employer, did not ensure that employees of J & D Stucco Inc. were protected from objects falling from overhead in that toeboards were not erected along all scaffold platforms on which employees were working at a firehouse under construction at 2201 Lake Ave. in Pueblo, Colorado. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $0
- · Z (S) $0
More inspections in this industry (NAICS 236220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332824101.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.