WASHINGTON, MO ·
OSHA Inspection: CANAM
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CANAM in 2000 WEST MAIN STREET, WASHINGTON, MO 63090 (NAICS 332312). OSHA activity number 332825538.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CANAM
- Site address
- 2000 WEST MAIN STREET
- City
- WASHINGTON
- State
- MO
- ZIP
- 63090
- Mailing
- 2000 WEST MAIN STREET, WASHINGTON, MO 63090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 102
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 28, 2012
- Abate by
- Sep 19, 2012
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: In the sheer area, a pnomatic piston powering the small green chanal sheer was not guarded. employees working in the area were exposed to pinch hazard as the piston moved vertically.
Recent events (2)
- · I (S) $2520
- · Z (S) $3600
1910.212 A05
- Issued
- Aug 28, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: Line Wi Welding area, a six foot tall pedastel fan used by the welders on as needed basis, had a five inch opening at the center. The condtion exposed the employees to amputation and or laceration hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B01
- Issued
- Aug 28, 2012
- Abate by
- Sep 19, 2012
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Near Line WI of the welding area, a metal electrical outlet box used to power the pedestal fan had the conductor wires exposed to damage. The outer insulation sheath was pulled awy from the box. This condtion exposed the employees to electrical hazards. b) Near Line WI of the welding area, an electrical junction box used to power a light fixture had conducter wires exposed to damage. The outer insulation sheating was not connected to the strain relief.
Recent events (2)
- · I (S) $1890
- · Z (S) $2700
More inspections in this industry (NAICS 332312)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332825538.