Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C.E. BOLLMEIER CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of C.E. BOLLMEIER CO. in 101 CASS AVE, SAINT LOUIS, MO 63102 (NAICS 237110). OSHA activity number 332828177.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C.E. Bollmeier CO. — free Get an email when a new federal OSHA severe-injury report for C.E. Bollmeier CO. is published. One employer, no account, unsubscribe in one click.
Establishment
C.E. BOLLMEIER CO.
Site address
101 CASS AVE
City
SAINT LOUIS
State
MO
ZIP
63102
Mailing
310 OLD DORSETT, MARYLAND HEIGHTS, MO 63043
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 11, 2012
Abate by
May 2, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees:    The employer failed to provide an egress ladder within a trench that measured at least 5 feet, 2 inches in depth.  Workers were exposed to a cave-in hazard.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.651 K01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Apr 11, 2012
Abate by
May 2, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.651(k)(1):     Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:     No person conducted an inspection of the excavation in which an employee was verifying a utility at this job site.  The employee was working in a trench that measured approximately 5 feet, 2 inches in depth (near where the employee was observed working), at least 3 feet in width, and at least 15 feet in lenght.  The excavation side walls and end walls were vertical and the side walls were composed of clay like soil of type B consistency.  No benching, shoring or sloping of excavation walls had been done.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 11, 2012
Abate by
May 2, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:       The employer allowed an employee to work in an unprotected trench that measured approximately 5 feet, 2 inches in depth (near where the employee was observed working), at least 3 feet in width, and at least 15 feet in lenght.  The excavation side walls and end walls were vertical and the side walls were composed of clay like soil of type B consistency.  No benching, shoring or sloping of excavation walls had been done.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332828177.