Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FUTUREMARK PAPER COMPANY

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of FUTUREMARK PAPER COMPANY in 13101 S. PULASKI ROAD, ALSIP, IL 60803 (NAICS 322121). OSHA activity number 332833748.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Futuremark Paper Company — free Get an email when a new federal OSHA severe-injury report for Futuremark Paper Company is published. One employer, no account, unsubscribe in one click.
Site address
13101 S. PULASKI ROAD
City
ALSIP
State
IL
ZIP
60803
Mailing
13101 S. PULASKI ROAD, ALSIP, IL 60803
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322121
Employees
150
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 150 exposed
Issued
Jun 4, 2012
Abate by
Jul 17, 2012
Penalty
Initial $4,500 · Current $3,150 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to combustible paper dust deflagration, explosion or other fire hazards while working at or near an indoor dust collector (bag house) which was not adequately designed to prevent or minimize employee exposure in the event of deflagration or other uncontrolled fire event:    Baled News Warehouse:  On or about March 27, 2012, the indoor Air Equipment & Engineering Inc. pneumatic pulse type bag house dust collector handling combustible paper dust lacked means of (1) explosion protection and (2) fire protection.    AMONG OTHER METHODS, A FEASIBLE METHOD TO CORRECT THIS HAZARD WOULD BE TO COMPLY WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD 654 "STANDARD FOR THE PREVENTION OF FIRE AND DUST EXPLOSIONS FROM THE MANUFACTURING, PROCESSING, AND HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS (2006)" SECTIONS 7.1.2; 7.13.1.1; 7.13.1.2; 7.13.1.3.1; 9.1.1.1; 10 AND/OR TO COMPLY WITH FM GLOBAL PROPERTY LOSS PREVENTION DATA SHEETS 7-76 "PREVENTION AND MITIGATION OF COMBUSTIBLE DUST EXPLOSIONS AND FIRE (2006)" SECTIONS 2.3; 2.4 AND 2.5 AND 7-73 "DUST COLLECTORS AND COLLECTION SYSTEMS (2008)" SECTION 2.1. SPECIFICALLY, THESE METHODS FOR EXPLOSION PROTECTION INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: (1) LOCATE THE DUST COLLECTOR IN A SAFE LOCATION OUTDOORS AND PREVENT DEFLAGRATION PROPAGATION BACK INTO THE FACILITY VIA A LISTED DEFLAGRATION ISOLATION DEVICE; OR (2) EQUIP THE INDOOR DUST COLLECTOR WITH DEFLAGRATION VENTING THAT IS VENTED THROUGH DUCTS TO THE OUTSIDE OF THE FACILITY IN ACCORDANCE WITH NFPA 68 "STANDARD ON EXPLOSION PROTECTION BY DEFLAGRATION VENTING", OR (3) INSTALL DEFLAGRATION SUPPRESSION SYSTEMS IN ACCORDANCE WITH NFPA 69 "STANDARD ON EXPLOSION PROTECTION SYSTEMS".  METHODS FOR FIRE PROTECTION INCLUDE, BUT ARE NOT LIMITED TO, AUTOMATIC SPRINKLER PROTECTION WITHIN THE DUST COLLECTOR ITSELF.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4500

View Futuremark Paper Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332833748.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.