BOISE, ID —
OSHA Inspection: BOISE METAL WORKS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BOISE METAL WORKS, INC. in 11345 PRESIDENT DRIVE, BOISE, ID 83713 (NAICS 332313). OSHA activity number 332834829.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOISE METAL WORKS, INC.
- Site address
- 11345 PRESIDENT DRIVE
- City
- BOISE
- State
- ID
- ZIP
- 83713
- Mailing
- P.O. BOX 190002, BOISE, ID 83719
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 14
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 20, 2012
- Abate by
- Aug 3, 2012
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of crushing injuries while operating powered industrial trucks: a) On or about 3/27/2012, and at times prior thereto, the Nissan LPG powered industrial truck did not have a seatbelt installed. Note 1: Abatement certification is required. Note 2: One feasible and acceptable abatement method to correct this hazard is to install a seat belt.
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
1910.178 L03 I M
- Issued
- Jul 20, 2012
- Abate by
- Aug 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(3)(i)(M): Any other operating instructions, warnings, or precautions listed in the operator's manual for the types of vehicle that the employee is being trained to operate. a) At the shop: On or about 3/27/2012, and at times prior thereto, the employer did not provide operators with instructions, warnings or other precautions for the Nissan LPG powered industrial truck. Note: Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Jul 20, 2012
- Abate by
- Jul 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a) At the shop; On or about 3/27/2012, and at times prior thereto, the employer did not have a list of certified trained powered industrial truck operators with the date of their last evaluation. Note: Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Jul 20, 2012
- Abate by
- Aug 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1):A powered industrial truck was found to be in need of repair, defective, or in any way unsafe, the truck was not taken out of service until it has been restored to safe operating condition. a) At the shop: On or about 3/27/2012, and at times prior thereto, the Nissan LPG powered industrial truck transmission would not stay in gear. b) At the shop; On or about 3/27/2012, and at times prior thereto, the Gradall rough terrain powered industrial truck had a broken window that was held with duct tape. Note: Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A02
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $1,530 · Current $765 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): The safety guard did not cover the spindle end, nut, and flange projections. The safety guard was not mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard: a) At the shop; On or about 3/27/2012, and at times prior thereto, the safety guard on the spindle end of the Baldor bench grinder was missing. Note: Abatement certification is required.
Recent events (2)
- — I (S) $765
- — Z (S) $1530
1910.215 A04
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch (0.125 inches) to prevent the work from being jammed between the wheel and the rest: a) In the shop: On or about 3/27/2012,, and at times prior thereto, the work rest on the Baldor bench grinder was 4/8 inches from the grinding wheel. Note: Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Safety guards were not adjusted so that the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch: a) At the shop: On or about 3/27/2012, and at times prior thereto, the tongue guard of the Baldor bench grinder was missing. Note: Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.36 D01
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employees were unable to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors: a) At the south east corner of the shop: On or about 3/27/2012, and at times prior thereto, the exit door was secured by a large barrel bolt. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B02
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit." a) At the south east corner of the shop: on 3/27/2012, and at times prior thereto, the exit did not have an exit sign. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C01
- Issued
- Jul 20, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was isolated from the energy source and rendered inoperative: a) The shop: On or about 3/27/2012, and at times prior thereto, energy control procedures (lock out/tag out) had not been developed for equipment such as but not limited to the water jet cutter, iron worker, shear, brake, powered industrial trucks, and band saws. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 A03 II
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, were not guarded. The guarding device was not in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, was not so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a) At the shop; On or about 3/27/2012, and at times prior thereto, the Black and Decker 10 inch Chop saw was missing the lower blade guard. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 B
- Issued
- Jul 20, 2012
- Abate by
- Jul 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air was used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) In the shop: On or about 3/27/2012, and at times prior thereto compressed air used for cleaning was 70 pounds per square inch at the tip of the nozzle. (b) In the shop: On or about 3/27/2012, and at times prior thereto, compressed air used for cleaning was 100 pounds per square inch at the tip of the nozzle. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Jul 20, 2012
- Abate by
- Jul 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(C): The work space was not clear and extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of this section. However, other equipment associated with the electrical installation and located above or below the electric equipment may extend not more than 153 mm (6 in.) beyond the front of the electric equipment: a) The distribution panel in the north east corner of the shop: On or about 3/27/2012, and at times prior thereto, the area in front of the circuit breaker panel box was obstructed by scrap metal, empty cardboard boxes and lumber. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 I
- Issued
- Jul 20, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. a) In the shop: On or about 3/27/2012, and at times prior thereto, the power cord on the Milwaukee right angle grinder was missing the ground pin. b) In the shop: On or about 3/27/2012, and at times prior thereto, the Ellis band saw power cord was missing the ground pin and was damaged. Note: Abatement certification is required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Boise Metal Works, INC.
View Boise Metal Works, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332313)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332834829.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.