NAMPA, ID ·
OSHA Inspection: THE CAMCO GROUP, LLC DBA C.M.C. CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE CAMCO GROUP, LLC DBA C.M.C. CONSTRUCTION in 15556 NORTH KODEE WAY, NAMPA, ID 83651 (NAICS 236116). OSHA activity number 332835248.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE CAMCO GROUP, LLC DBA C.M.C. CONSTRUCTION
- Site address
- 15556 NORTH KODEE WAY
- City
- NAMPA
- State
- ID
- ZIP
- 83651
- Mailing
- 3313 WEST CHERRY LANE #144, MERIDIAN, ID 83642
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 2
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- Apr 23, 2012
- Abate by
- Jun 5, 2012
- Penalty
- Initial $1,728 · Current $1,728
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a) All areas of the site including the structure's interior/exterior: On or about March 27, 2012, and at times prior thereto, the employer did not develop and/or implement an accident prevention program to identify and prevent/eliminate hazards including but not limited to struck by falling tools or materials, falls from stairs and upper levels, unguarded power tools and/or contact with energized electrical circuits. Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (S) $1728
1926.20 B02
- Issued
- Apr 23, 2012
- Abate by
- Apr 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) All areas of the site including the structure's interior/exterior: On or about March 27, 2012, and at times prior thereto, the employer did not have a competent person performing frequent and regular inspections to identify and prevent/eliminate hazards including but not limited to struck by falling tools or materials, falls from stairs and upper levels, unguarded power tools and/or contact with energized electrical circuits. Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (S) $0
1926.28 A
- Issued
- Apr 23, 2012
- Abate by
- Apr 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there was an exposure for hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to employees. a) Main front entrance and side areas: On or about March 27, 2012, and at times prior thereto, as the controlling employer, various subcontractors' employees without hard hats were walking/working under or in close proximity to a tubular welded scaffold plastering work was being performed overhead. Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (S) $0
1926.501 B13
- Issued
- Apr 23, 2012
- Abate by
- Apr 24, 2012
- Penalty
- Initial $1,296 · Current $1,296
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Main entrance area of the structure; On or about March 27, 2012, and at times prior thereto, as the controlling employer, a subcontractor's employees were accessing the 2nd level landing while performing miscellaneous carpentry work. The landing did not have guardrails or another means of fall protection in place. b) Main entrance area of the structure; On or about March 27, 2012, and at times prior thereto, the superintendent was accessing the 2nd level landing to access the apartments. The landing did not have guardrails or another means of fall protection in place. Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (S) $1296
1926.1052 C01 II
- Issued
- Apr 23, 2012
- Abate by
- Apr 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Main entrance area of the structure, 1st to 2nd level; On or about March 27, 2012, and at times prior thereto, as the controlling employer, a subcontractor's employees were utilizing a stairway to access the 2nd level apartments to perform miscellaneous carpentry. The stairway did not have a stairrail system in place. b) Main entrance area of the structure, 1st to 2nd level; On or about March 27, 2012, and at times prior thereto, the superintendent was utilizing a stairway to access the 2nd level apartments. The stairway did not have a stairrail system in place. Note: Abatement certification IS required for this item.