BOISE, ID —
OSHA Inspection: MICRON TECHNOLOGY, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MICRON TECHNOLOGY, INC in 8000 S. FEDERAL WAY, BOISE, ID 83707 (NAICS 334413). OSHA activity number 332835818.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MICRON TECHNOLOGY, INC
- Site address
- 8000 S. FEDERAL WAY
- City
- BOISE
- State
- ID
- ZIP
- 83707
- Mailing
- P.O. BOX 6; MAIL STOP 1-602, BOISE, ID 83707
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- Employees
- 6000
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 26, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of explosions from a copper exhaust line: a) Fabrication 4: On or about March 27, 2012, and times prior thereto, employees were exposed to an explosion from a copper exhaust line on an Asher Tool that was incompatible with the anhydrous ammonia (NH3) with which it was used. Copper piping may become brittle and thinned by the NH3 and eventually plugged by the formation of AN (ammonium nitrate) and TACN (tetramine copper II nitrate). A restriction in the line can cause the internal pressure and friction of the line to increase and detonate the TACN (a highly sensitive explosive from the reaction of the copper line material and NH3) followed by the detonation of the AN. The construction plans for the facility, approved by the employer, called for the required stanless steel piping, but for reasons unknown to the employer, copper piping was utilized. b) Fabrication 4: On or about March 27, 2012, and times prior thereto, the dry pump pressure and system operation was not sufficiently monitored for pressure changes and proper operation. Employees were exposed to an explosion hazard from a copper exhaust line that had become internally restricted by chemical build up inside the line increasing the pressure in the line to over 1600 mbar. The equipment monitoring SCADA system had been non-operational for 2 days and the fault paging system had been out-of-service for the prior two months.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
More inspections at Micron Technology, INC
View Micron Technology, INC's full OSHA safety record →
More inspections in this industry (NAICS 334413)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332835818.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.