On , OSHA opened a planned safety inspection of TEGRANT CORPORATION PROTEXIC BRANDS in 210 SPRING STREET, EAU CLAIRE, WI 54703 (NAICS 322211). OSHA activity number 332836139.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tegrant Corporation Protexic Brands — free Get an email when a new federal OSHA severe-injury report for Tegrant Corporation Protexic Brands is published. One employer, no account, unsubscribe in one click.
Site address
210 SPRING STREET
City
EAU CLAIRE
State
WI
ZIP
54703
Mailing
210 SPRING STREET, EAU CLAIRE, WI 54703
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
36
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 exposed
Issued
May 17, 2012
Abate by
Jun 1, 2012
Penalty
Initial $3,740 · Current $2,244 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  (a) Main production floor; Written machine specific energy control procedures for the Herman Schwabe, Inc., die cutter, did not include the stored hydraulic and mechanical energies.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3740

1910.147 D04 I

Serious 1 exposed
Issued
May 17, 2012
Abate by
Jun 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Main production floor; Employees conducted numerous die changes daily and did not lock out the Herman die cutter machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 exposed
Issued
May 17, 2012
Abate by
Jun 8, 2012
Penalty
Initial $3,740 · Current $2,244 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, and rotating parts:  (a) Main production floor; The manual Herman press was not guarded where the ram meets the stationary platen.  (b) Main production floor; The backside of the manual Herman press was not properly guarded.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3740

1910.212 A03 II

Deleted Serious Gravity 5 1 exposed
Issued
May 17, 2012
Abate by
Jun 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  (a) Hallway; An Edge-Sweets vertical band saw was inadequately guarded.  (b) Corrugated fabrication area; The 4 bar slitter rotary knives were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 exposed
Issued
May 17, 2012
Abate by
May 24, 2012
Penalty
Initial $3,740 · Current $2,244 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed:  (a) Main production floor; The 480 volt electrical panel for the Herman press had 3 open holes.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3740

1910.213 S06

Other-than-serious 1 exposed
Issued
May 17, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  (a) Wood shop; Wood dust from the table saw accumulated on an electrical switch that controlled the enclosureless dust collection system.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332836139.