NORTH CANTON, OH —
OSHA Inspection: COMMERCIAL ROOFING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COMMERCIAL ROOFING INC. in ACROSS FROM 6370 STRIP AVE., NORTH CANTON, OH 44720 (NAICS 238160). OSHA activity number 332838424.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMMERCIAL ROOFING INC.
- Site address
- ACROSS FROM 6370 STRIP AVE.
- City
- NORTH CANTON
- State
- OH
- ZIP
- 44720
- Mailing
- 341 2ND DR. NE., NEW PHILADELPHIA, OH 44663
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 C02 IV
- Issued
- Apr 6, 2012
- Penalty
- Initial $2,640 · Current $1,848 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use: On or about 03/27/12 during the installation of a fall protection system and other construction activities, the employer did not ensure an all-terrain forklift that was lifting a wooden pallet which supported a scaffold platform was approved by the manufacturer for such use.
Recent events (2)
- — I (S) $1848
- — Z (S) $2640
1926.451 C02 V
- Issued
- Apr 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied: On or about 03/27/12 during the installation of a fall protection system and other construction activities, the employer did not ensure that an all-terrain forklift that was supporting a scaffold platform and a wooden pallet was secured to the forks to prevent movement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 K02
- Issued
- Apr 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(k)(2): All ladders used to support ladder jack scaffolds did not meet the requirements of subpart X of thispart -- Stairways and Ladders, except that job-made ladders shall not be used to support ladder jack scaffolds: On or about 03/27/12 during the installation of a fall protection system and other construction activities, the employer did not ensure that a portable stepladder that was used as a scaffold plank support met the requirements of subpart x. The stepladder was in the closed position and was leaning against a wall as it supported a scaffold plank.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 K05
- Issued
- Apr 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another: On or about 03/27/12 during the installation of a fall protection system and other construction activities, the employer did not ensure that a modified ladder jack scaffold platform was not bridged to a wooden pallet platform being supported by a forklift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Apr 6, 2012
- Penalty
- Initial $2,640 · Current $1,848 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about 03/27/12 during the installation of a fall protection system and other construction activities, the employer did not ensure a stepladder that was used to gain access to a scaffold platform was 3 feet above the scaffold platform-landing surface.
Recent events (2)
- — I (S) $1848
- — Z (S) $2640
1926.1053 B04
- Issued
- Apr 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about 03/27/12 during the installation of a fall protection system and other construction activities, the employer did not ensure a stepladder that was used to gain access to a scaffold platform was used as recommend by the manufacturer. The stepladder was leaning against the scaffold platform in the closed position.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Apr 6, 2012
- Penalty
- Initial $13,200 · Current $9,240 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 03/27/12 during the erection of a ladder jack scaffold, the employer did not ensure employees used fall protection devices/system when working on/fom a roof which was 14 feet above a lower level. COMMERICAL ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD CFR 1926.501(B)(10), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314844648, CITATION NUMBER 01, ITEM NUMBER 01 AND WAS AFFIRMED AS A FINAL ORDER ON 10/27/10, WITH RESPECT TO A WORKPLACE LOCATED AT 6304 MAYFIELD RD., MAYFIELD HTS., OHIO 44124. COMMERICAL ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD CFR 1926.501(B)(10), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313782237, CITATION NUMBER 01, ITEM NUMBER 02 AND WAS AFFIRMED AS A FINAL ORDER ON 04/27/10, WITH RESPECT TO A WORKPLACE LOCATED AT REST AREA # 0204 SR-2 WEST, PORT CLINTON, OHIO 44452.
Recent events (2)
- — I (R) $9240
- — Z (R) $13200
More inspections at Commercial Roofing INC.
View Commercial Roofing INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332838424.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.