AUBURN, NY —
OSHA Inspection: TRW AUTOMOTIVE, U.S. LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRW AUTOMOTIVE, U.S. LLC in 2150 CRANEBROOK DRIVE, AUBURN, NY 13021 (NAICS 336399). OSHA activity number 333290799.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRW AUTOMOTIVE, U.S. LLC
- Site address
- 2150 CRANEBROOK DRIVE
- City
- AUBURN
- State
- NY
- ZIP
- 13021
- Mailing
- 2150 CRANEBROOK DRIVE, AUBURN, NY 13021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 215
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jul 13, 2012
- Abate by
- Aug 12, 2013
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) TRW Automotive, U.S. LLC, on or about 6/21/12: The employer has not conducted a periodic or more frequent inspection of their energy control procedures to ensure that the requirements of the standard were being followed. Employees perform servicing and maintenance on machines and equipment such as but not limited to: Calvary Pre-Heat & Selective Solder System, Automated Robot and Gasket/PCBA/Battery Assembly to Housing machine.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.147 C07 I
- Issued
- Jul 13, 2012
- Abate by
- Aug 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) TRW Automotive , U.S., LLC, on or about 6/21/12: The employer did not provide training to authorized and affected employees to ensure that the energy control program was understood and that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices. Employees perform service and/or maintenance on equipment, including but not limited to, Selective Solder Systems, Shaker, Automated Robot and Assembly Machines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Jul 13, 2012
- Abate by
- Feb 13, 2013
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a) TRW Automotive, U.S., LLC, on or about 6/28/12: Unqualified employees were performing servicing and/or maintenance, including troubleshooting on live electrical equipment, were not provided training in regards to safety related work practices and the use of personal protective equipment.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.333 B02 I
- Issued
- Jul 13, 2012
- Abate by
- Feb 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives: a) Througout the facility, on or about 6/21/12: There were no written safety related work practice procedures in place to prevent electric shock or other injuries to employees when working on machines and equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Jul 13, 2012
- Abate by
- Feb 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: a) TRW Automotive, U.S., LLC, on or about 6/28/12: Unqualified employees performing troubleshooting on or near live electrical equipment up to 480 volts, were not provided with appropriate personal protective equipment in that they wear conductive jackets.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at TRW Automotive, U.S. LLC
View TRW Automotive, U.S. LLC's full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333290799.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.