MEQUON, WI —
OSHA Inspection: SUPER SKY PRODUCTS ENTERPRISES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUPER SKY PRODUCTS ENTERPRISES, LLC in 10301 N. ENTERPRISE DR., MEQUON, WI 53092 (NAICS 332321). OSHA activity number 333290971.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPER SKY PRODUCTS ENTERPRISES, LLC
- Site address
- 10301 N. ENTERPRISE DR.
- City
- MEQUON
- State
- WI
- ZIP
- 53092
- Mailing
- 10301 N. ENTERPRISE DR., MEQUON, WI 53092
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 63
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 18, 2012
- Abate by
- Jun 11, 2012
- Penalty
- Initial $3,273 · Current $2,291 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): (a) The employer did not outline the specific steps to shutting down and isolating hazardous energies, applying lockout/tagout devices, and testing equipment/machinery to verify the effectiveness of the lockout/tagout devices. This exposed employees to amputation hazards.
Recent events (2)
- — I (S) $2290.75
- — Z (S) $3272.5
1910.147 C06 I
- Issued
- May 18, 2012
- Abate by
- Jun 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a)The employer did not inspect/evaluate each authorized employee at least annually on the energy control procedure developed by the employer. This exposed employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- May 18, 2012
- Abate by
- Jun 11, 2012
- Penalty
- Initial $3,273 · Current $2,291 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: (a) The employer failed to evaluate forklift operators at least every three years to ensure their competency in the proper operation of the forklifts. This exposed employees to struck-by hazards.
Recent events (2)
- — I (S) $2290.75
- — Z (S) $3272.5
1910.212 A01
- Issued
- May 18, 2012
- Abate by
- Jul 2, 2012
- Penalty
- Initial $5,390 · Current $3,773 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) The employer failed to ensure that employees, working at 10301 North Enterprise Drive in Mequon, Wisconsin, were protected from the point of operation, cutting table, and other moving parts on the Shoda CNC machine. This exposed employees to amputation hazards.
Recent events (2)
- — I (S) $3773
- — Z (S) $5390
1904.29 B01
- Issued
- May 18, 2012
- Abate by
- May 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail as required by the regulation. (a) The employer did not complete the OSHA Form 300 as required; in that column F of the 2012 Log did not contain the part of the body affected and the object/substance which directly injured or made the employee ill.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.22 A02
- Issued
- May 18, 2012
- Abate by
- May 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floors of every workroom were not maintained in a clean condition: (a) The area around the Shoda CNC Machine had accumulation of metal shavings.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Super SKY Products Enterprises, LLC
View Super SKY Products Enterprises, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333290971.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.