Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LEE E. LEVESQUE JR GENERAL CONTRACTORS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LEE E. LEVESQUE JR GENERAL CONTRACTORS in 1055 E. GENESEE ST, SYRACUSE, NY 13205 (NAICS 238160). OSHA activity number 333291078.

Watch LEE E. Levesque JR General Contractors — free Get an email when a new federal OSHA severe-injury report for LEE E. Levesque JR General Contractors is published. One employer, no account, unsubscribe in one click.
Site address
1055 E. GENESEE ST
City
SYRACUSE
State
NY
ZIP
13205
Mailing
72 WEST 1ST STREET, FULTON, NY 13069
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system:      a) South side roof of Buildling "B", on or about 3/30/12: Two employees engaged in roof work on a low sloped roof were not protected from falling 48 feet 6 inches to grade.    b) South side roof of Building "B", on or about 4/2/12: An employee engaged in roofing work on a low sloped roof was not protected from falling 48 feet 6 inches to grade.
Recent events (3)
  • — J (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1926.502 D15

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.    a) On the roof of Building "B", on or about 4/2/12: The anchorage point being used by the owner of the company to secure his fall protection was not installed properly. Only one side of the bracket was secured to the roof deck, the manufacturer requires both sides to be secured.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:    a) At the jobsite, on or about 3/30/12: Employees engaged in roofing work were not provided with fall protection training to be able to recognize and avoid fall hazards.    b) At the jobsite, on or about 4/2/12: Employees engaged in roof work were not provided with fall protection training to be able to recognize and avoid fall hazards.
Recent events (3)
  • — J (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333291078.