Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: WEB COMMUNICATIONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEB COMMUNICATIONS in 301 W MAIN ST, PLYMOUTH, PA 18651 (NAICS 323110). OSHA activity number 333292589.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WEB Communications for free Get an email when a new federal OSHA severe-injury report for WEB Communications is published. One employer, no account, unsubscribe in one click.
Establishment
WEB COMMUNICATIONS
Site address
301 W MAIN ST
City
PLYMOUTH
State
PA
ZIP
18651
Mailing
PO BOX 190, PLYMOUTH, PA 18651
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
19
Ownership type
A

5 citations on file for this inspection.

1910.37 A02

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2012
Abate by
May 10, 2012
Penalty
Initial $3,500 · Current $1,000 Reduced
29 CFR 1910.37(a)(2):   Exit routes were not arranged so that employees would not have to travel toward a high hazard area and the path of travel was not effectively shielded from the high hazard area by suitable partitions or other physical barriers:  a) Old bindery: Propane and kerosene containers were stored next to the rear exit door exposing workers to a higher hazard area in the event of an emergency, on or about March 23, 2012.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $1000
  • · Z (S) $3500

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2012
Abate by
Jun 15, 2012
Penalty
Initial $3,500 · Current $1,000 Reduced
29 CFR 1910.219(d)(1):   Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a) Baler Room: a set of belt-driven pulleys on the shredder feed for the baler where not fully enclosed by a guard exposing workers to an in-going nip point hazard, on or about March 23, 2012.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $1000
  • · Z (S) $3500

1910.219 E03

Serious Gravity 5 1 instance 1 exposed
Issued
May 3, 2012
Abate by
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3):   Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section:  a) Baler Room: A set of three incline belts on the shredder feed were not fully enclosed by a guard exposing workers to an entanglement hazard, on or about March 23, 2012.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
May 3, 2012
Abate by
Jun 2, 2012
Penalty
Initial $3,500 · Current $2,500 Reduced
29 CFR 1910.303(b)(2):   Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Bindery area: A pendent type receptacle installation was installed using an unapproved metal box exposing workers to an electric shock hazard, on or about March 23, 2012.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $2500
  • · Z (S) $3500

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
May 3, 2012
Abate by
Jun 15, 2012
Penalty
Initial $3,500 · Current $2,500 Reduced
29 CFR 1910.305(g)(2)(iii):   Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) In the bindery area: Conductors entering the plug on the Ultrafold 714 were not provided with strain relief exposing the terminal connections to pulls and workers to an electric shock hazard, on or about March 23, 2012.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $2500
  • · Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333292589.