OSHA Inspection: GFRC AQUISITION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GFRC AQUISITION, LLC in 3725 E. TEXAS ST., BOSSIER CITY, LA 71111 (NAICS 327390). OSHA activity number 333292787.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gfrc Aquisition, LLC — free Get an email when a new federal OSHA severe-injury report for Gfrc Aquisition, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3725 E. TEXAS ST.
City
BOSSIER CITY
State
LA
ZIP
71111
Mailing
3725 E. TEXAS ST., BOSSIER CITY, LA 71111
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
21
Ownership type
A

9 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 11, 2012
Abate by
Jun 11, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that each saw was properly guarded.  This condition was observed on or about March 22, 2012, where the portion of the saw blade above the table on a Ridgid table saw (Model TS3660; S/N P080411848) was not enclosed by an adjusting hood, exposing the operator to amputation/laceration hazards.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.243 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 11, 2012
Abate by
Jun 21, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that each portable grinder was properly guarded.  This condition was observed on or about March 22, 2012, where a Craftsman 7-inch industrial angle grinder (Model 900.277120, S/N 049097) did not have an abrasive wheel guard installed, exposing employees to amputation, laceration and/or struck-by hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.305 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 11, 2012
Abate by
Jun 16, 2012
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that each unused circuit breaker opening was effectively closed.  This condition was observed on or about March 22, 2012, in the welding shop area, where there was a circuit breaker opening in a Square D electrical panelboard, exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1910.305 G02 III

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 11, 2012
Abate by
Jun 16, 2012
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:    At 3725 E. Texas St., Bossier City, LA 71111; on or about March 22, 2012, the strain relief was damaged on the electrical cord of a MillerMillermatic 212 welding machine being used in the welding shop, exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1800

1910.334 A02 I

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Jun 11, 2012
Abate by
Jun 16, 2012
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that electrical cords were visually inspected for external defects before each use:    a)  In the welding shop; on or about March 22, 2012, there was insulation damage (with exposed wiring) on the electrical cord of a Craftsman 7 industrial angle grinder (Model 900.277120, S/N 049097), exposing employees to the hazard of electrical shock.    b)  In the welding shop; on or about March 22, 2012, the electrical plug pins and plug outer jacket on the electrical cord of a Craftsman 7 industrial angle grinder (Model 900.277120, S/N 049097) were damaged and unsuitable for safe use, exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2400

1904.29 B03

Other-than-serious 1 instance 21 exposed
Issued
Jun 11, 2012
Abate by
Jun 12, 2012
Penalty
Initial $600 · Current $300 Reduced
29 CFR 1904.29(b)(3): Each recordable injury or illness was not entered on the OSHA 300 Log and/or an incident report OSHA Form 301or equivalent) within seven (7) calendar days of receiving information that a recordable injury or illness has occurred:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that each work-related recordable case is entered on the OSHA 300 Log.  This condition was determined on or about March 22, 2012 where the following case was not entered on the OSHA 300 Log for year 2011 within seven days after receiving information:    Employee (Case No.1) fell off a ladder while attempting to install plywood to the ceiling of a shelter and injured right knee that resulted in job transfer or restrictions of 55 days.
Recent events (2)
  • — I (O) $300
  • — Z (O) $600

1904.32 B06

Other-than-serious 1 instance 21 exposed
Issued
Jun 11, 2012
Abate by
Jun 12, 2012
Penalty
Initial $600 · Current $300 Reduced
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1 and April 30:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that the OSHA 300A Summary of Work-Related Injuries and Illness form was posted.  This condition was observed on or about March 22, 2012 where the certified OSHA 300A for year 2011 was not posted for employees to view.
Recent events (2)
  • — I (O) $300
  • — Z (O) $600

1910.157 E01

Other-than-serious 1 instance 21 exposed
Issued
Jun 11, 2012
Abate by
Jun 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that all portable fire extinguishers were inspected and tested.  This condition was observed on or about March 22, 2012 in the welding shop area and throughout the site where portable fire extinguishers had not received an annual maintenance inspection since year 2004 and were not visually inspected by the employer at least monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 3 exposed
Issued
Jun 11, 2012
Abate by
Jun 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident:    At 3725 E. Texas St., Bossier City, LA 71111; the employer did not ensure that each breaker box was labeled.  This condition was observed on or about March 22, 2012, in the welding shop area, where two electrical panelboards were not labeled to indicate what each circuit breaker is used for.