Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NEATON AUTO PRODUCTS MANUFACTURING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEATON AUTO PRODUCTS MANUFACTURING, INC. in 975 S. FRANKLIN ST, EATON, OH 45320 (NAICS 326199). OSHA activity number 333296374.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Neaton Auto Products Manufacturing, INC. for free Get an email when a new federal OSHA severe-injury report for Neaton Auto Products Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
975 S. FRANKLIN ST
City
EATON
State
OH
ZIP
45320
Mailing
975 S. FRANKLIN ST, EATON, OH 45320
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
725
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 26, 2012
Abate by
May 17, 2012
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices shall be affixed to each energy isolating device by authorizedemployees.    a) Lockout device was not attached to the energy isolating point during the adjustment and/or cleaning of the Robot  spray paint nozzle.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $7000

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 26, 2012
Abate by
May 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3):     Machine or equipment isolation. All energy isolating devices that are needed to control the energyto the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energysource(s).    a) Electrical disconnect(s) on the C#5 Paint line, Robot spray painting area, were not actuated to disable power while making adjustments and/or cleaning of the spray painting nozzle.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 26, 2012
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operatorand other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips andsparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a) Guarding on the C#5 paint line was inadequate in that the light curtain did not work to prevent movement of the rotating table.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $7000