Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ALCOA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALCOA in PARK AVENUE EAST, MASSENA, NY 13662 (NAICS 331312). OSHA activity number 333298172.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alcoa for free Get an email when a new federal OSHA severe-injury report for Alcoa is published. One employer, no account, unsubscribe in one click.
Establishment
ALCOA
Site address
PARK AVENUE EAST
City
MASSENA
State
NY
ZIP
13662
Mailing
PARK AVENUE EAST, PO BOX 150, MASSENA, NY 13662
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331312
Employees
750
Ownership type
Private (A)

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $7,000 · Current $6,000 Reduced
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards associated with dust explosions, deflagrations, and other fire hazards.      On or about 3/29/2012, West Cast House:  The dust collection system associated with the chip melter #2 was not designed to prevent or minimize damage that would occur in the event of a dust explosion, deflagration or fire.    Among other methods, a feasible abatement method to correct this hazard is to comply with NFPA 484 Standard for Combustible Metals, 2009.  Including but not limited to:         1) Keeping dry type collectors outside as referenced in Section 6.3.2.5.        2) Provide deflagration venting as referenced in Section 6.3.5.6.    Abatement documentation is required for this item.
Recent events (3)
  • · J (S) $6000
  • · C (S) $7000
  • · Z (S) $7000

1910.22 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    On or about 3/29/2012, West Cast House:  Housekeeping to remove and control the amount of combustible dust was not performed on routine basis except in the immediate work area around the chip melter.      Abatement documentation is required for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.145 C03

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):    On or about 3/29/2012, West Cast House, Chip Melter #2 dust collection system:  Safety instruction signs regarding the hazards and potential existence of combustible dusts were not posted.    Abatement documentation is required for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.134 G04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $5,000 · Current $4,000 Reduced
29 CFR 1910.134(g)(4)(i): During interior structural firefighting, at least two employees did not enter the immediately dangerous to life and health atmospheres and/or remain in visual or voice contact with one another at all times:    On or about 3/29/2012, West Cast House:  An employee engaged in structural firefighting activities entered into the burning structure alone.       Abatement certification is required for this item.
Recent events (3)
  • · J (S) $4000
  • · C (S) $5000
  • · Z (S) $5000

1910.134 G04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(4)(ii):     During interior structural firefighting, at least two employees were not located outside the immediately dangerous to life or health atmosphere to provide assistance or emergency rescue:    On or about 3/29/2012, West Cast House:  An employee engaged in structural firefighting activities entered into the burning structure alone while there was only one trained person the exterior present.       Abatement certification is required for this item.
Recent events (3)
  • · J (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.156 E02 I

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 24, 2012
Abate by
Oct 16, 2012
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.156(e)(2)(i): Foot and leg protection did not meet the requirements of paragraphs (e)(2)(ii) and (e)(2)(iii) of this section:    On or about 3/29/2012, West Cast House:  All employees that are part of the Fire Brigade were not provided with foot and leg protection that meets the National Fire Protection Association (NFPA) standard NFPA No. 1971 - 1975 "Protective Clothing for Structural Fire Fighting"     Abatement certification is required for this item.
Recent events (3)
  • · J (S) $5000
  • · C (S) $5000
  • · Z (S) $5000

View Alcoa's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333298172.