SOUTHWEST HARBOR, ME ·
OSHA Inspection: THE TALARIA COMPANY LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of THE TALARIA COMPANY LLC in 130 SHORE ROAD, SOUTHWEST HARBOR, ME 04679 (NAICS 336612). OSHA activity number 333303626.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE TALARIA COMPANY LLC
- Site address
- 130 SHORE ROAD
- City
- SOUTHWEST HARBOR
- State
- ME
- ZIP
- 04679
- Mailing
- 130 SHORE ROAD, SOUTHWEST HARBOR, ME 04679
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 57
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 18, 2012
- Abate by
- Apr 21, 2012
- Penalty
- Initial $4,675 · Current $3,506 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: Carpentry Area - The upper section of the mezzanine platform did not have a top guard rail which exposed employees to a fall of 8 feet to the first floor.
Recent events (2)
- · I (S) $3506
- · Z (S) $4675
1910.213 B03
- Issued
- Apr 18, 2012
- Abate by
- Apr 21, 2012
- Penalty
- Initial $4,675 · Current $3,506 Reduced
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: Main Line, Pre-Fab Area - The employer did not ensure that the Rockwell tablesaw was equiped with a anti-restart safety device.
Recent events (2)
- · I (S) $3506
- · Z (S) $4675
1910.305 B01
- Issued
- Apr 18, 2012
- Abate by
- Apr 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: Main Line , Boiler Room - The electrial panel had two missing knockout plugs located on the bollom of the panel.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.37 B02
- Issued
- Apr 18, 2012
- Abate by
- Apr 21, 2012
- Penalty
- Initial $2,805 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": In the following locations , exit signs were not placed at egress doors: 1. First Floor Service Office. 2. Second Floor Service Office. 3. Main Entrance of Retail Store. 4. Sales Office.
Recent events (2)
- · I (O) $0
- · Z (S) $2805
More inspections at The Talaria Company LLC
View The Talaria Company LLC's full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333303626.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.