MILWAUKEE, WI ·
OSHA Inspection: MAYNARD STEEL CASTING COMPNAY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAYNARD STEEL CASTING COMPNAY in 2856 SOUTH 27TH STREET, MILWAUKEE, WI 53215 (NAICS 331513). OSHA activity number 333307056.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAYNARD STEEL CASTING COMPNAY
- Site address
- 2856 SOUTH 27TH STREET
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53215
- Mailing
- 2856 SOUTH 27TH STREET, MILWAUKEE, WI 53215
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 250
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.252 A01 II
- Issued
- Sep 13, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.252(a)(1)(ii): When the object to be welded or cut could not be moved and all the fire hazards could not be removed, guards were not used to confine the heat, sparks, and slag to protect the immovable fire hazards: (a) Employees were exposed to fire hazards while welding/cutting on the RotoBlaster and the employer did not ensure that all fire hazards, such as but not limited to, rubber lining inside the RotoBlaster were protected from heat, sparks, and slag.
Recent events (2)
- · I (S) $6300
- · Z (S) $6300
1910.252 A02 III A
- Issued
- Sep 13, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(iii)(A): The employer did not provide fire watchers whenever welding or cutting was performed in locations where other than a minor fire might develop: (a) Employees were exposed to fire hazards while welding/cutting on the RotoBlaster which was lined with a cumbustible rubber lining and the employer did not ensure that a fire watch was provided where fire might develop.
Recent events (2)
- · I (S) $0
- · Z (S) $6300
1910.252 A02 XIII
- Issued
- Sep 13, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(xiii): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment on its property, in accordance with 29 CFR 1910.252 (a)(2)(xiii)(A) through 29 CFR 1910.252(a)(2)(xiii)(D) (a) Employees were exposed to fire hazards while welding/cutting on the RotoBlaster which was lined with a cumbustible rubber lining and the employer did not recognize its responsibility for the safe usage of cutting or welding equipment on its property.
Recent events (2)
- · I (S) $0
- · Z (S) $6300
1910.252 A02 XIV A
- Issued
- Sep 13, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(xiv)(A): The employer did not ensure that the supervisor was responsible for the safe handling of the cutting or welding equipment and the safe use of the cutting or welding process: (a) Employees were exposed to fire hazards while welding/cutting on the RotoBlaster which was lined with a cumbustible rubber lining and the employer did not ensure that the supervisor was responsible for the safe handling of the cutting or welding equipment and the safe use of the cutting or welding process.
Recent events (2)
- · I (S) $0
- · Z (S) $6300
1910.252 A02 II
- Issued
- Sep 13, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(ii): Suitable extinguishing equipment was not maintained in a state of readiness for instant use: (a) Employees were exposed to fire hazards while welding/cutting on the RotoBlaster which was lined with a cumbustible rubber lining and the employer did not enusre suitable extinguishing equipment was maintained in a state of readiness.
Recent events (2)
- · I (S) $0
- · Z (S) $6300
More inspections in this industry (NAICS 331513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333307056.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.