Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: CAN DO CONSTRUCTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAN DO CONSTRUCTION in 602 JACK LAMBERT APT. D,E,F & G, SWEETWATER, TX 79556 (NAICS 236115). OSHA activity number 333310894.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CAN DO Construction for free Get an email when a new federal OSHA severe-injury report for CAN DO Construction is published. One employer, no account, unsubscribe in one click.
Establishment
CAN DO CONSTRUCTION
Site address
602 JACK LAMBERT APT. D,E,F & G
City
SWEETWATER
State
TX
ZIP
79556
Mailing
6372 CO RD 324, HAWLEY, TX 79525
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
5
Ownership type
Private (A)

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2012
Abate by
Aug 20, 2012
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:      On March 1, 2012, and at times prior thereto, at the job site locatd at 602 Jack Lambert Drive Apt. D,E,F, & G, Sweetwater, Texas 79556, an employee installing double top plate on walls and ceiling joist was exposed to falling more than 6 feet to the lower level.
Recent events (1)
  • · Z (S) $1800

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Aug 20, 2012
Penalty
Initial $1,350 · Current $1,350
29 CFR 1926.1053(b)(1):   Portable ladder was used for access to an upper landing surface, the ladder shall be secured at its top to a rigid support:      On March 1, 2012, and at times prior thereto, at the job site located at 602 Jack Lambert Drive Apt. D,E,F, & G, Sweetwater, Texas 79556.  Employees were exposed to fall hazards while accessing the roof with a ladder that was not secured to a rigid support.
Recent events (1)
  • · Z (S) $1350

1926.1053 B06

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 13, 2012
Abate by
Aug 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6):  Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement:      On March 1, 2012, and at times prior thereto, at the job site located at 602 Jack Lambert Drive Apt. D,E,F, & G, Sweetwater, Texas 79556.  Employees ascending and descending to and from the double plate using a ladder that was not erected on a flat stable surface.  This condition exposed employees to potential fall hazards.
Recent events (1)
  • · Z (S) $0

1926.404 B01 III C

Other-than-serious 1 instance 4 exposed
Issued
Aug 13, 2012
Abate by
Aug 20, 2012
Penalty
Initial $0 · Current $0
1926.404(b)(1)(iii)(C):  Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which were fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage.  Equipment found damaged or defective was not removed from service until repaired.      On March 1, 2012, and at times prior thereto, at the job site located at 602 Jack Lambert Drive Apt. D,E,F, & G, Sweetwater, Texas 79556, employees were exposed to electrocution hazards while operating equipment connected to a flexible cord without a grounding pin.
Recent events (1)
  • · Z (O) $0

View CAN DO Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333310894.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.