OSHA Inspection: PAUL HUNTINGTON SALES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PAUL HUNTINGTON SALES in W5066 COUNTY HWY BE, BONDUEL, WI 54107 (NAICS 423110). OSHA activity number 333317923.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paul Huntington Sales — free Get an email when a new federal OSHA severe-injury report for Paul Huntington Sales is published. One employer, no account, unsubscribe in one click.
Site address
W5066 COUNTY HWY BE
City
BONDUEL
State
WI
ZIP
54107
Mailing
W5066 CTY HWY BE, BONDUEL, WI 54107
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423110
Employees
6
Ownership type
A

7 citations on file for this inspection.

1910.107 C06

Serious Gravity 5 4 instances 6 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.107(c)(6):     Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for     Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    a)   In the spray room being used for vehicle painting, electrical wiring was not explosion-proof type.    b)  In the spray room being used for vehicle painting, the ceiling fan was not explosion-proof type.    c)  In the spray room being used for vehicle painting, outlets and electrical boxes were not explosion-proof type.    d)  In the spray room being used for vehicle painting, the lighting fixtures were not explosion-proof type.        ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.107 C07

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(7):     Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles:    a)    Lighting in the spray room being used for vehicle painting was not totally enclosed.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 5 1 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.134(c)(1):     A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    a)    Company did not implement a respiratory program for employees doing the spray room painting of  vehicles.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.1200 E01

Serious Gravity 5 1 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.1200(e)(1):     Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):       a)    Company did not have a written hazard communication program for their employees.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.1200 F05 I

Serious Gravity 5 1 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    a)    Company did not have their cleaner and degreaser spray bottles labeled with their chemical name.      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 5 1 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii):     The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    a)    Company did not have all of their spray bottles labeled with appropriate hazard warnings.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 exposed
Issued
Apr 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1):     The employer did not have a material safety data sheet for each hazardous chemical in use:    a)    Company did not have a material safety data sheet for two of the paints used in the spray room. (Diamond Vogel, Cote-All, Multi-Purpose Enamel, AZ-5411 & Kirker Automotive Finish, Ultra-Glo, Acrylic Urethane, UA-41092)      ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0